background image

OPERATION 

 

Please read the following instructions very carefully before you start.  
This  pump  is  suitable  for  ponds,  aquariums,  fountains  and  water  features.  Jebao  pumps  are  safe  to 
function both indoors and outdoors, and must be fully submersed at all times. 
 

INSTALLATION 

 

 

The pump must always be fully submersed, and must never run dry.   

 

Place the pump on a stable surface that is free of sludge, sand and other debris. 

 

The  pump  is  best  placed  in  an  area  of  the  pond  where  the  water  will  get  maximum  circulation 
(inlet and outlet at opposite ends). 

 

The  electricity  supply  cord  to  the  pump  should  extend  in  a  loop  below  the  13-amp  plug  socket; 
this is to prevent water drops from making contact with the plug or electricity supply outlet. 

 

If  a  low  voltage  pump  is  being  used  the  transformer  must  be  kept  in  a  dry  area  as  it  is  not 
waterproof. 

 

It is recommend that a residual current device (RCD) with a rated residual operating current not 
exceeding 30mA be installed for the Pondline pump and any other electrical products used in or 
around the pond. 

 

MAINTENANCE & CLEANING 

 

Carry out routine maintenance regularly.  
The following maintenance and cleaning will improve the pumps performance and its life. 
Pumps  do  not  require  lubrication  or  special  maintenance.  The  pump  may  stop  working  if  the  water 
flow into the pump is reduced, this may be caused by grit or algae clogging the pump or debris lodged 
in between the impellor and wall of the pump. 

 

 

Turn off the power supply and move the pump to a dry location (do not use the power cable to lift 
the pump). 

 

Remove the front cage from the pump. 

 

The  impeller  is  situated  in  the  pump  housing  and  can  be  removed  by  turning  the  cover  anti-
clockwise to release. 

 

Pull the impeller assembly away from the pump body. 

 

When  disassembling  the  impeller  please  ensure  that  you  do  not  lose  the  small  plastic  washers 
positioned at the top and bottom of the impeller. These ensure the quiet and efficient operation 
of the pump. 

 

Check the “O” Ring of the pump body. 

 

Wash all parts with fresh water carefully to remove all accumulated debris. 

 

Place the impeller and shaft back in the pump and place the cover on the front. 

 

Put the pump back in the water making sure the pump is fully submersed. 

 

If the pump fails to operate, check the following: 

 

 

Check  the  power  socket  and  try  another  socket  to  ensure  the  pump  is  getting  electrical  power. 
NOTE: Always disconnect from electrical socket before handling the pump. 

 

Check the pump outlet and hose for kinks and obstructions. Algae may block them, flush out any 
blockages with the garden hose. 

 

Check the inlet to ensure it is not clogged with debris. 

 

Remove the pump inlet to access the impellor, remove the impellor to ensure it is not broken or 
jammed. 

 

Monthly maintenance will prolong your pumps life span. 

NOTE: Ensure that the electrical cord loops below the electrical outlet to form a ‘Drip Loop’. This will 
prevent water from running down the cord into the electrical socket.

 

 
LOW VOLTAGE PUMPS 

 

Low voltage pumps work under rated voltage and must be connected to the transformer provided.  
Always keep the transformer away from the pond in case of damage by water or humidity. 

The 

transformer is not waterproof therefore must be kept in a dry area.  

It is recommended that a 

residual current device (RCD) with a rated residual operating current not exceeding 30mA be used in 
conjunction with the pump. 

 
SAFETY WARNINGS 

 

 

Make sure that the voltage and frequency of power supply comply with the specifications on the 
product. 

 

Never pull the pump or remove the pump by pulling the cord. 

 

Never remove the plug or shorten the cord (this may void the warranty) 

 

Keep the plug and socket dry, if low voltage make sure that the transformer is also kept in a dry 
place. 

 

The pump is not suitable for use in swimming pools or other situations where humans may make 
bodily contact with the water. 

 

Only use the Pondline pump in fresh water, do not use for flammable liquids or above 35°C. 

 

The  electrical  cable  cannot  be  replaced.  If  the  cord  is  damaged  the  appliance  should  be 
discarded. 

 

The electrical supply must be installed by a registered electrician. 

 

Always turn the unit off before cleaning or removing the pump for maintenance. 

 

The pump is only suitable with a FI-switch 30mA and has to be connected to a regular safety plug 
socket. 

 

The transformer is not waterproof and must be kept in a dry area. 

 

Never let the pump run dry. 

 

Do not allow the pump to freeze in the winter. 

 

WARRANTY 

 

This  product  has  a  12  months  manufactures  warranty  (from  date  of  purchase)  against  mechanical  or 
material  defects  and  does  not  apply  in  case  of  improper  use,  negligence,  lack  of  maintenance  or 
accidental damage either to the pump, the impeller or impeller shaft.  
The warranty may be void if damage is done to the product from abuse or negligence. 
The  manufacturer  or  distributor  shall  not  be  held  liable  for  any  damages  caused  by  defective 
components  or  materials,  or  for  loss  incurred  because  of  the  interruption  of  service  or  any 
consequential,  incidental  damages  or  expenses  arising  from  the  manufacture,  sale,  use  or  misuse  of 
this  product.    The  manufacturer  shall  not  be  held  responsible  for  any  loss  of  fish,  plants  or  other 
livestock as a result of any defect or failure of this product.   
This warranty excludes the sponge pre-filter and impeller which may require replacing annually. 
 

In the event of a warranty claim, please contact your supplier with the original receipt for repair or 
exchange

.   

 

 

 

Reviews: