17
SEAL ASSEMBLY
Install Slinger O-Ring (4.9) onto the shaft ensuring the O-ring is all the way up the shaft
and against the pump body bore face. This is also visible through the slots in the sides of
the pump body.
•
Install external O-rings (4.5) and internal Quad-ring (4.8) to the Seal body (4.5)
•
Install the seal housing into the pump assembly. Aligning the flush holes with the
tapping in the pump body.
•
Install the flush locking adapter O-ring onto the adapter (5.1).
•
Install the flush locking adapter (5.1) such that the end of the component is locking
the seal body in position.
•
Install the primary O-ring (4.6) onto the Static Seal (4.3).
•
Install the static seal face (4.3) aligning the slots in the seal face with the anti-rotation
pins in the seal body.
•
Install the rotor and rotary seal face assembly.
Fig. 23
Summary of Contents for AccuLAB Series
Page 1: ...Operating Maintenance Manual JEC AccuLAB Series Rotary Lobe Pumps...
Page 4: ...3...
Page 5: ...4...
Page 6: ...5...
Page 7: ...6...
Page 23: ...22 DIMENSIONAL DRAWING FOR BARE SHAFT...
Page 24: ...23 PARTS LIST EXPLODED VIEW...