background image

 

 

 

 

 

SAFETY

 

 
 

DO’S & DON’TS 

 

DO read and understand these instructions before installing or using the pump.   

DO use JEC spare parts when replacing a component of the pump. 

DO NOT services the pump while it is running. 

DO NOT place the pump in an application where the service ratings are exceeded. 

DO NOT modifies the pump. Modifying the pump creates unsafe conditions and voids all   

warranties. 

 

 

SAFETY PRECAUTIONS WHEN INSTALLING PUMP 

   

DO use an authorized electrician when connecting the pump. 

DO observe the mechanical limits of the pump (refer to the pump performance sheet). 

DO install a throttling valve in the discharge line. 

DO NOT installs a throttling valve in the suction line. 

 

 

SAFETY PRECAUTIONS WHEN OPERATING PUMP 

 

DO only qualified personnel should operate this pump. 

DO NOT start the pump until all personnel are clear. 

DO  NOT  touches  the  pump  or  the  lines  when  pumping  hot  fluids  or  when  performing 

Clean In Place (CIP) procedures.   

DO NOT run the pump with BOTH the suction inlet and discharge outlet blocked. Running 

the pump with the inlet the blocked will cause serious damage to the pump. 

DO NOT checks pump rotation with liquid in the pump. 

DO NOT runs the pump with the front cover removed. The

 

screws and screw case

 

could 

be damaged or may cause severe injury. 

DO NOT operates the pump with removed the safety guard or shroud. 

 

 

SAFATY PRECAUTIONS WHEN SERVICING PUMP 

 

DO ensure the pump is cool to touch before performing service. 

DO  relieve  all  pressure  and  drain  all  fluids  from  pump  and  connected  piping  before 

performing service. 

DO  ENSURE  POWER  TO  THE  UNIT  HAS  BEEN  UNPLUGGED  PRIOR  TO 

PERFORMING ANY PUMP MAINTENANCE OR CLEANING. 

DO exercise caution and wear protective clothing when using lye or acid for cleaning. 

 

 

 
 
 
 

Summary of Contents for AccuLAB Series

Page 1: ...Operating Maintenance Manual JEC AccuLAB Series Rotary Lobe Pumps...

Page 2: ...ranty INSTALLATION Installation Start Up TROUBLESHOOTING Troubleshooting MAINTENANCE Disassembly Inspection Pump housing assembly Shaft and bearing replacement Seal assembly Rotor Clearance Rotor Timi...

Page 3: ...cation beyond the intended use or conversion of the pump without written agreement with the manufacturer shall be deemed to be not in accordance with the intended use The pump may only be started up f...

Page 4: ...3...

Page 5: ...4...

Page 6: ...5...

Page 7: ...6...

Page 8: ...pump DO NOT start the pump until all personnel are clear DO NOT touches the pump or the lines when pumping hot fluids or when performing Clean In Place CIP procedures DO NOT run the pump with BOTH th...

Page 9: ...ing hereunder or for negligence for any and all losses and damages resulting from any cause shall be either the repair or replacement of defective components or pumps verified by JEC In no event inclu...

Page 10: ...n cannot be seen look through the pump case adaptor after takeoff motor shroud Bump means to momentarily apply power to the motor and then immediately remove power 3 Direction of rotating must only be...

Page 11: ...temp Leaks in piping or pump Dissolved gas in product Mechanical noise Excessive weight from piping Pump body distorted Excessive discharge pressure Worn bearing Worn gears Rotor to Rotor contact Inc...

Page 12: ...ad prior to disassembly The pump head may be isolated with inlet and outlet valves And disconnect the suction and discharge piping from the pump Loosen and remove the four cover bolts from the cover R...

Page 13: ...order to remove stationary seals both of seal stopper pin on the top and bottom should be loosened as shown Rotary seal rings are being installed into rotors with rotary seal ring rubber cap Remove s...

Page 14: ...scoring or cracks Replace any seal faces that are damaged 3 Inspect shaft shoulder matched to rotors and other metal parts for wear or damage 4 Inspect rotor galling sign among the rotor housing fron...

Page 15: ...commended torque To tighten the second rotor place the plastic dowel on the opposite side of the rotor and tighten the second rotor bolt to the proper torque Excessive torque could make rotor bolts da...

Page 16: ...ar housing Generally gear housing is no needed for the maintenance disassembly or assembly except filling grease into bearing and gear or maintenance for the gear If gear housing is needed for the mai...

Page 17: ...and bearing can be dismantled easily by using two long bolts as shown Be careful not to damage the shaft with excess hitting WARNING Bearings on drive and idle shaft can be dismantled Shim should be...

Page 18: ...the seal housing into the pump assembly Aligning the flush holes with the tapping in the pump body Install the flush locking adapter O ring onto the adapter 5 1 Install the flush locking adapter 5 1...

Page 19: ...Rotor tip clearance not adjustable and set by manufacturer Front and back face clearance adjustable by shim Rotor width and body depth are fixed at manufacture Therefore with the correct rotor 1 1 si...

Page 20: ...tor timing is determined by the relative location of the two helical gears 3 2 on the shafts 5 Place the wooden dowel between the rotors 6 Bend away the tab of the lock washer 3 3 on one shaft Loosen...

Page 21: ...shaft gear keys to the 12 00 position Place the gear lock washer 3 3 and lock nut 3 3 onto the shafts and hand tighten After the gears are installed turn the shafts to make sure they turn freely and t...

Page 22: ...dB MATERIALS Product Wetted Steel Parts SUS316L standard Product Wetted Seals EPDM standard Alternative Seals NBR FPM PTFE Encapsulated Perfluoro elastomer SHAFT SEALS Seal type Single and Double Mech...

Page 23: ...22 DIMENSIONAL DRAWING FOR BARE SHAFT...

Page 24: ...23 PARTS LIST EXPLODED VIEW...

Page 25: ...over Bolt SUS304 M6 x 15 4 2 5 Bearing Cover Ass y Pin SUS304 5 x 11 5 2 3 1 Drive Shaft SUS304 2 3 2 Helical Gear S45C 2 3 3 Lock Nut Washer S45C M20 x 1 2 3 4 Shaft Bearing 32004XJ 4 3 5 Rotor Bolt...

Page 26: ...eproduced copied duplicated or transmitted in any form or by any means electronic or mechanical photocopying recording for any purpose without any consent or expressed permission of JEC Ltd Copyright...

Reviews: