background image

IL n. 321
EDIZ. 01/11/2013

JEDI

ELECTROMECHANICAL ACTUATOR FOR SPRING 
AND COUNTERWEIGHT BALANCED DOORS

GB

www.remotecontrolgates.co.uk

Summary of Contents for JEDI-700

Page 1: ...IL n 321 EDIZ 01 11 2013 JEDI ELECTROMECHANICAL ACTUATOR FOR SPRING AND COUNTERWEIGHT BALANCED DOORS GB www remotecontrolgates co uk...

Page 2: ...Directive 2004 108 EC Radio Directive 99 05 EC Directive ROHS2 2011 65 EC The relevant technical documentation is available at the national authorities request after justifiable request to V2 S p A Co...

Page 3: ...or operation in dry rooms exclusively For the safety and life of persons it is absolutely necessary to follow all instructions Keep these instructions save for later reference Do not permit children t...

Page 4: ...easily without any friction The door must be properly balanced both before and after its automation stopping the door in any position it must not move carry out a balance weight adjustment if necessa...

Page 5: ...the connecting section bar R to the end position indicated by the two holes Q on the chain guide section bar 4 Adjust the tension of the chain using the Allen head screw with a 10 mm Allen wrench tur...

Page 6: ...actly half its height mark the reference points on the upper crossbeam and on the ceiling to facilitate positioning of the guide section bar 2 3 Fasten the bracket E to the upper crossbeam of the door...

Page 7: ...in the same plane If not add shims Connect the perforated bar L to the perforated bar of the arch arm using 2 6 x 15 bolts RELEASE OF THE AUTOMATION In order to release the automation from inside pul...

Page 8: ...The control panel inside JEDI is already cabled You just need to plug it in the electrical outlet to proceed with operational parameter programming To connect the photocells and the START button plea...

Page 9: ...nd then repeat the programming operation 1 Setting the open limit switch mPLEASE NOTE The open limit switch must be stored prior to the close limit switch If this procedure is used erroneously to set...

Page 10: ...parameters set press and hold the key for 5 seconds until the segments of the display illuminate one at a time until showing 0 mPLEASE NOTE if this parameter is modified then on completion of programm...

Page 11: ...enance alarm default 0 function deactivated If this function is activated the device emits BEEPs when the motor reaches 2000 operational cycles This alarm may be useful for scheduling maintenance oper...

Page 12: ...fter approx 1 second Release the key and press the remote control button twice the device emits a BEEP and the display is turned off to confirm memorising has been successful Press and hold key 0 appe...

Page 13: ...ENGLISH 24...

Reviews: