S
YSTEM CONNECTIONS
(시스템 연결 방법)
E/M, R/M, TEL PWR CON
L
N
E
24V/1.5A
DC OUTPUT
24V/1.5A
SWITCHED TOTAL MAX OUTPUT 7000VA. SWITCHED EACH MAX OUTPUT 3500VA.
DC 24V
EQUIPMENT
ONLY.
DC 24V OUTPUT
SERIAL NO.:
(TO JRG-220A)
(TO JEP-352)
POWER OUTPUTS DELAY SOCKET(1 6) FOR POWER AMPLIFIERS.
UNSWITCHED MAX 360VA
9
8
7
6
5
4
3
2
1
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
230V / 50Hz
24V
SWITCHED IN
PWR CONTROL IN
UNSWITCHED IN
TO OTHER
JPD-322A
WARNING:
TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK DO NO T EXPOSE
THIS EQUIPMENT TORAIN OR MOISTURE.
MODEL NO.: JPD-322AU
POWER CHECK
(NON PULSE)
5
FROM LINE LEVEL SIGNAL
M
A
IN
A
C
P
O
W
ER
PRE AMP ONLY
BATTERY
G
E/M DATA
E/M
LINK
INPUT
G
FROM JSS-120A
TO RELAY BOX
UPPER JRG-220A
LOWER JRG-220A
FROM JPD-322A
AUDIO
IN
AUDIO
OUT
N.
O
CO
M
+2
4V
OUT
EMERGENCY CARD
E/M
G
ND
G
DIRECT SPEAKER SELECTOR DATA IN
TELEPHONE PAGING CARD
TEL AUDIO IN
+5V OUT
10 9 8 7 6 5 4 3 2 1
20 19 18 17 16 15 14 13 12 11
G
LINK
INPUT
REMOTE AUDIO IN
REMOTE ZONE DATA OUT
AMP PRIORITY CONTROL OUT
REMOTE DATA
FROM JDR-104 / JRA-051A
FROM JSS-120A
REMOTE-1 CARD
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
DC OUTPUTS
T40AL 32V
T40AL 32V
T20AL 32V
T20AL 32V
T20AL 32V
CAUTION
:
IN CASE OF USING EXTERNAL
EXTERNAL
BATTERY
24V
CAUTION:
TO REDUCE
THE RISK OF
FIRE REPLACE ONLY WITH SAME TYPE FUSE.
SERIAL NO.:
UNSWITCHED OUT
1
2
3
4
5
EMERGENCY POWER SUPPLY
MADE IN KOREA
MODEL NO.: JEP-352U
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
24V
SWITCHED OUT
PWR CONTROL OUT
(FROM JPD-322A)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
FUSE RATING
T2AH 250V
AC 230V 50Hz 105W
BATTERY, INTERNAL BATTERY IS NOT AVAILABLE.
BE SURE NOT TO EXCEED 24A OF DC OUTPUTS
FOR USING OF INTERNAL BATTERY.
EACH
24V/32A
EACH
24V/16A
POWER
CHECK
AKU 40%
CHECK
(NON PULSE)
(NON-PULSE)
USE ONLY WITH A 250V FUSE
40
40
20
20
20
JCU-160
IN
OUT
RS-232C
UNIT NO. RESET
DC INPUT
SUM OUTPUT
24V
INPUT
CHECK SIGNAL
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
CH 9
1
8
CH 10
CH 11
CH 12
CH 13
CH 14
CH 15
CH 16
1
8
9
16
9
16
NON PULSE
PULSE
CHANNEL USE
OFF
ON
POWER CHECK
(NON PULSE)
FD-20 SLOT
Priority
Relay
C
O
M
N
.O
N
.C
Ground
Lift
AC POWER
REMOTE
SERIAL NO.:
G
C
O
M
25
V
50
V
10
0V
C
O
M
1.
3
5.
2
20
.8
AC 230V /50Hz 1420W
MODEL.: JPA-
1 CHANNEL P.A POWER AMPLIFIER
MADE IN KOREA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
480DPT
G
Off :
Fault
On :
Normal
G
GND
OUT
PRI
CTL
24V
400Hz
Normal
FD20
Max 0.5A
0dBu(0.775V)
Priority Input
60k BAL
0dBu(0.775V)
PGM Input
60k BAL
Le
ve
l
0
10
DC POWER
24V/40A
DC
FUSE
FAN
AC
FUSE
Fault
Balanced Outputs
RMS 480W
FD-20 SLOT
FD-20 SLOT
AMP-2
AMP-1
Priority
Relay
C
O
M
N
.O
N
.C
Priority
Relay
C
O
M
N
.O
N
.C
Lift
Ground
Balanced Outputs
RMS 240W
Balanced Outputs
RMS 240W
AC POWER
REMOTE
G
MODEL.: JPA-2240DPT
2 CHANNEL P.A POWER AMPLIFIER
MADE IN KOREA
C
O
M
C
O
M
25
V
50
V
10
0V
2.
6
10
.4
41
.7
C
O
M
2.
6
10
.4
41
.7
C
O
M
25
V
50
V
10
0V
AC 230V /50Hz
1300W
DC POWER
24V/40A
SE
R
IA
L
N
O
.:
DC
FUSE
FAN
AC
FUSE
Fault
G
G
G
G
GND
OUT
PRI
CTL
24V
GND
OUT
PRI
CTL
24V
PRI
Level
PRI
Level
Max 0.5A
Max 0.5A
0dBu(0.775V)
Priority Input
60k BAL
0dBu(0.775V)
PGM Input
60k BAL
0dBu(0.775V)
Priority Input
60k BAL
0dBu(0.775V)
PGM Input
60k BAL
AMP-2
AMP-1
400Hz
Normal
FD20
Off :
Fault
On :
Normal
400Hz
Normal
FD20
Off :
Fault
On :
Normal
0
10
Level
PRI
Level
PRI
0
10
AMP-3
AMP-2
AMP-1
AMP-4
AMP-3
AMP-2
AMP-4
FD-20 SLOT
M
O
D
EL
.:
JP
A
-4
24
0D
PT
4
CH
AN
NE
L
P.
A
PO
W
ER
A
M
PL
IF
IE
R
M
A
D
E
IN
K
O
R
EA
C
A
U
TI
O
N
RI
SK
O
F
EL
EC
TR
IC
S
HO
CK
DO
N
OT
O
PE
N
WA
RN
IN
G:
TO
R
ED
UC
E
TH
E
RI
SK
O
F
FI
RE
OR
E
LE
CT
RI
C
SH
OC
K
DO
N'
T
EX
PO
SE
T
HI
S
EQ
UI
PM
EN
T
TO
R
AI
N
O
R
M
O
IS
TU
RE
.
G
G
G
G
G
G
G
Level
PRI
CTR
GND
24V
OUT
PRI
Max 0.5A
0dBu(0.775V)
Priority Input
60k BAL
0dBu(0.775V)
PGM Input
60k BAL
Lift
Ground
PER
BE SURE TO LINK 1 2
FOR DC POWER
2
2
1
1
AMP-1
SERIAL NO.:
AC POWER
REMOTE
G
100V
50V
25V
COM
AC 230V /50Hz
2500W
On : Normal
Off : Fault
40
0H
z
N
or
m
al
F
D
20
Level
PRI
Level
PRI
Level
PRI
G
0
10
DC POWER
24V/80A
N . C
COM
N . O
RM
S
24
0W
Ba
la
nc
ed
O
ut
pu
ts
Priority
Relay
41.7
10.4
2.6
COM
DC
FUSE
FAN
AC
FUSE
Fault
10
10
9
8
7
6
SERIAL NO.:
AUX INPUT
DC POWER
5
4
3
2
1
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN KOREA
MODEL NO.: JMU-307A
MONITOR UNIT
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
0dB 600
BALANCED MONITOR INPUTS (1V~100V) 10K
AC 230V 50Hz 20W
FUSE RATING
T200mAL 250V
G
CAUTION:
TO REDUCE
THE RISK OF FIRE REPLACE
ONLY WITH SAME TYPE FUSE.
USE ONLY WITH A 250V FUSE
JCU-160
JMU-307A
JPA-480DPT
JPA-2240DPT
JPA-4240DPT
JRG-220AU
(JRG-220A)
JPD-322AU
(JPD-322A)
JEP-352U
(JEP-352)