Read and ensure that you understand all of the operating instructions, safety precautions and warnings in this Instruction  

 

 

Manual before operating or maintaining this compressor. Most accidents that result from compressor operation and  

 

 

 

maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by   

 

 

recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.  Hazards   

 

 

that must be avoided to prevent bodily injury or machine damage are identified by warnings on the compressor and in this  

 

 

Instruction Manual. Never use this compressor or modify it in any way that has not been specifically recommended by the  

 

 

manufacturer. Contact a qualified electrician for advice on any issues relating to electrical safety in your working environment.

ELECTRICAL SAFETY

Ensure that you check the equipment thoroughly to ensure it is safe and fit for purpose before each use.  It is important that 
you inspect all plugs, sockets, power cables and electrical fittings for wear and damage and repair or replace any defective 
components.  The risk of electric shock can be minimised by the correct use of the appropriate electrical safety devices. 

• 

We recommend that you fit a 

Residual Current Circuit Breaker (RCCB)

 in the main distribution board and that a 

Residual Current Device 

(RCD)

 is used when operating this equipment. 

• 

The 

Electricity at Work Act 1989 

includes legislation that places legal implications on employers to ensure the safety of electrical devices 

in the workplace. The regulations dictate that all portable equipment must be inspected regularly and tested to ensure that it is safe for use. 
'Portable equipment' means any electrical item that can be moved and this is often referred to as 

Portable Appliance Testing (PAT)

. PAT 

testing should be carried out regularly on this equipment by trained, authorised personnel, as required by the legislation.  

• 

The 

Health and Safety at Work Act 1974

 states that it is the responsibility of the owner of electrical appliances to ensure that both the 

equipment and working environments are maintained to ensure safe operation at all times.   

• 

Check that all equipment cables are secure, correctly insulated, free from damage, and protected against short circuit and overload before 
connecting to the power supply. Do not use worn or damaged cables, plugs, sockets or other fittings.  

• 

Ensure that the power supply matches voltage requirements specified on the equipment and that the plug is wired correctly and fitted with 
the correct fuse.  

• 

If the electrical fuse blows, ensure it is replaced by an identical type of fuse with the same rating.  

• 

Never pull or manoeuvre this equipment into position using the power cable (move using the handle).  

• 

Ensure the power cable is kept away from heat, oil and sharp edges. 

• 

We recommend that the equipment is connected directly to the power supply without the use of extension leads as the resulting voltage drop 
can reduce motor and pump performance. 

• 

Always disconnect the compressor from the power source and remove the compressed air from the air tank before servicing, inspecting, 
maintaining, cleaning, replacing or checking any parts. 

• 

Do not carry the compressor while it is connected to its power source or when the air tank is filled with compressed air. Be sure the pressure 
switch is in the 

“Off”

 position before connecting the compressor to its power source. 

• 

Do not use the compressor in damp / wet conditions.  
 
 

  SAFETY GUIDELINES 

 

Summary of Contents for JEFC050L08B Series

Page 1: ...User Manual v 1 2 JEFC050L08B Series...

Page 2: ...USER MANUAL JEFC050L08B Series 50L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 2...

Page 3: ...rmation to ensure its correct and safe use We recommend that this manual is read before any operation or before performing any kind of adjustment to the product and prior to any maintenance tasks By f...

Page 4: ...essure 8bar 116psi 8bar 116psi Wheel Diameter 150mm 150mm Lubrication Semi Synthetic SAE30 Optional 15W 40 220 cc Semi Synthetic SAE30 Optional 15W 40 220 cc Weight NW 36kg GW 39kg NW 36kg GW 39kg Equ...

Page 5: ...dot indicates the low mark Important Always ensure that the oil level is correct before operating the compressor Ensure working environment is suitable for use This compressor must be used on a flat...

Page 6: ...t all portable equipment must be inspected regularly and tested to ensure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portab...

Page 7: ...ir vent must be kept clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or...

Page 8: ...in a confined area with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nyl...

Page 9: ...sure gauge The compressor will now operate automatically The pressure switch stops the motor when the maximum tank pressure is reached and restarts it when the pressure falls below the minimum thresho...

Page 10: ...d service agent There is a leak from the base of the pressure switch when the compressor is stopped The Non return valve from the tank is leaking Disassemble and clean if necessary replace valve inser...

Page 11: ...onnected from the power source Allow the compressor pump and other parts to cool off if changing oil after use Ensure compressor is on a flat and level surface Remove fill cap plug and place collectio...

Page 12: ...USER MANUAL JEFC050L08B Series 50L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 12 PARTS DIAGRAM MAIN ASSEMBLY...

Page 13: ...Hex Bolt 8 1 Mini Ball Valve 9 2 Washer 10 2 Wheel 11 2 Axle 12 2 Plate Washer 13 2 Washer Spring 14 2 Hex Nut 15 1 Air Tank 16 2 Hex Bolt 17 6 Hex Bolt 18 4 Plate Washer 19 1 Check Valve 20 2 Sleeve...

Page 14: ...USER MANUAL JEFC050L08B Series 50L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 14 PARTS DIAGRAM PUMP...

Page 15: ...1 Rotor Ass y 41 2 Stud Bolt 12 1 Oil Seal 42 2 Hex Nut 13 1 Head Bolt 43 1 Gasket Valve 14 1 Bearing 6204 44 2 Valve Plate 15 1 Hex Nut 45 1 Gasket Valve 16 1 Washer Spring 46 2 Blade Valve 17 1 Cran...

Page 16: ...uropean Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European...

Page 17: ...ka Cesta 56 821 01 Bratislava Country Slovakia 1354 2011 65 EU as amended RoHS Directive Intertek Testing Services Shanghai Block B Jinling Business Square No 801 YiS han Road Shanghai China 200233 00...

Page 18: ...as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect wil...

Page 19: ...and in need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructe...

Page 20: ...rk Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating...

Reviews: