3.

 

Insert the Extracting Tube ( L ) into   

the dipstick hole until it reaches the   

bottom of the oil pan.   
Connect the Main Suction Tube ( K ) 

into the Fluid Inlet Coupler ( J ) with 

the Main Suction Tube Adapter. 
The Main Suction Tube ( K ) will 

connect to the Extracting Tube ( L ) 

with the Extracting Tube Adapter. 

 

 

 

4.

 

Lift the Handle ( H ) of the                

Hand Pump ( G ) to the top position       

and press it to the bottom position   

repeatedly.   

The Extractor Unit will start operation. 

 

 

 

 

 

 

 

 

 

 

 

5.

 

When the fluid inside the extractor tank 

    reaches 

Full

position, the Extractor 

    Unit will shut off automatically, the 

    Handle ( H ) of the Hand Pump 

    ( G ) will lock. Push the Release 

    Button ( B ) on the side of the 

    Cover Housing (A ), and then press 

    the Handle ( H )of the Hand 

    Pump( G ) to the bottom position 

    to release Hand Pump from locked 

    position. 

 

 

 

 
 

Summary of Contents for 555-23560

Page 1: ...OPERATING INSTRUCTIONS AND PART MANUAL 555 23560 9 LITER MANUAL FLUID EXTRACTOR CAREFULLY READ THIS MANUAL BEFORE OPERATING THE UNIT...

Page 2: ...t use the unit to extract siphon or store petroleum or other highly inflammable liquids Do not throw drop or mishandle the unit Do not disassemble tamper with or modify the unit for any other purpose...

Page 3: ...Extractor Unit Tube Storage Unit Main Suction Tube Extracting Tube Brake Tube With Rubber Fitting Contents of Package Instructions Manual 2...

Page 4: ...A Cover Housing B Release Button C Reservoir Tank D Tube Storage Unit E Footboard F Base G Hand Pump H Handle I Fluid Outlet Housing J Fluid Inlet Coupler K Main Suction Tube L Extracting Tube M Brak...

Page 5: ...engine oil first you need to make sure the vehicle is level and then run the engine for about 5 minutes to warm the oil and allow any sludge or contamination within the oil to mix Operating Steps 1 To...

Page 6: ...Adapter 4 Lift the Handle H of the Hand Pump G to the top position and press it to the bottom position repeatedly The Extractor Unit will start operation 5 When the fluid inside the extractor tank rea...

Page 7: ...the laws and guidelines in your state Trouble shooting No Trouble Cause Trouble shooting 1 When the Extractor Unit is working but it can t suck the fluid any more Check that the extraction tube has b...