CHARGING & RECHARGING INSTRUCTIONS 
 

CAUTION 

 

Ensure that the unit power push-button is in the off position.  

 

This  product  may  arrive  partially  charged  from  the  manufacturer.  It  is  recommended  to  fully  charge  the  unit 
immediately after purchase and before using for the first time. 

 

Recharge immediately when red LED (25%) is flashing due to jump starter battery low voltage. Fully recharge the 
jump starter, when charge status is 50%. Once unit is 100% charged, all LEDs lights will turn off. To check status, 
press power push-button one time. 

 

The charging LED indicators will be illuminated while charging, showing 25%, 50%, 75%, & 100%. 

 

It is recommended that the jump starter is in an upright position while charging. 
 

2.

 

IMPORTANT:

 THE 120 VOLT AC POWER UNIT (CHARGER) IS INTENDED  TO BE CORRECTLY ORIENTED IN A 

VERTICAL OR FLOOR MOUNT POSITION DURING CONNECTION TO A 120V AC RECEPTACLE. 

3.

 

 

NOTE:

 ENSURE BOTH BOOSTER CLAMPS (POSITIVE & NEGATIVE) ARE PLACED IN THEIR STORAGE 

HOLDERS WHEN NOT IN USE & DURING THE JUMPSTARTER RECHARGING. 
 

CHARGING WITH 120 VOLT AC CHARGER 

1. Insert the 120V AC charger plug into the jump starter charging port. 

4.

 

2. Insert the 120V AC charger transformer plug into a 120V AC receptacle. 

5.

 

3. Fully charge the unit according to the following: 

 

Initial & first time charge: charge until LED charge status lights turn off. 

 

Recharge or between each use: 6 to 8 hours. 

4. Charging LEDS will turn off once 100% status is achieved. Press power push-button to verify 100% charging status. 
When charging is complete unplug the 120V AC charger transformer plug first and then the 120V AC charger plug from 
the charging port on the jump starter. 
 

SPECIFICATIONS 

1.  BUILT IN BATTERY: 33 AMP HOUR (Ah) LITHIUM COBALT BATTERY 
2.  STARTING CURRENT: 12V/700A : 24V/350A 
3.  PEAK CURRENT: 12V/1400A : 24V/700A 
4.  USB PORT: 5V DC/ 2.4A 
5.  LED LIGHT: 12V DC/ 2 LED (2W/330mA) 
6.  PROTECTIONS:  OVER  CURRENT,  LOW  VOLTAGE,  OVER  &  REVERSE  CHARGE,  REVERSE  POLARITY, 

OVER TEMPERATURE, SHORT CIRCUIT 

7.  OPERATING TEMP: -40° F - 1400° F 
8.  NET WEIGHT: 6.8 1b 
9.  UNIT DIMENSIONS: 9.5" (H) x 10.6" (W) x 5" (D) 

 

STORAGE 

Store in cool, dry, well ventilated area with overhead cover. This unit may be stored in any position. Ensure that the 
booster clamps are secured to their storage holders.  
 

NOTE:

 Jump starter output & power buttons must be in the off positions. If not used for prolonged time, recharge every 

3 months. 

 

                                         1-800-345-4545   jegs.com

 

Summary of Contents for 81952

Page 1: ... battery being jumped when making final connection Working around lead acid batteries may be dangerous Lead acid batteries generate explosive gases during normal charging and jump starting operations All lead acid batteries car truck boat produce hydrogen gas which may violently explode in the presence of fire or sparks DO NOT smoke use matches lighters or open flame near batteries DO NOT operate ...

Page 2: ...iece of metal to prevent short circuits and arching Avoid dropping metal tools onto vehicle battery It might spark or short circuit battery or other electrical parts that may cause short circuits or explosion Keep battery terminals clean Be careful to keep corrosion from coming in contact with eyes When using the 120V AC charger pull on the plug and never pull on the cord when disconnecting DO NOT...

Page 3: ... into the jump starter charging port 4 2 Insert the 120V AC charger transformer plug into a 120V AC receptacle 5 3 Fully charge the unit according to the following Initial first time charge charge until LED charge status lights turn off Recharge or between each use 6 to 8 hours 4 Charging LEDS will turn off once 100 status is achieved Press power push button to verify 100 charging status When char...

Page 4: ... possible Do not clamp directly to carburetor fuel lines or non grounded sheet metal body parts c See Jump Starting Battery Boost step 7 to continue Positive Grounded System a Securely connect the Negative Black clamp to the Negative NEG N ungrounded terminal of the vehicle battery b Securely connect the Positive Red clamp to the vehicle chassis engine block or a nonmoving grounded metal part of t...

Page 5: ...ower off the light press hold the power push button until lights turn off NOTE LED light emergency flasher SOS functions will operate in sequence to each other The lighting mode will depend on the prior last operating function selected User may have to cycle between modes in order to achieve the proper lighting function USB POWERED DEVICES 1 Prior to connecting the device to the unit s USB port ma...

Page 6: ...amps and use Jump starter with higher starting current 7 Have your vehicle alternator starter battery checked by a professional for repair 8 Ensure to verify the correct battery voltage from the vehicle s owner manual and follow jumpstarting battery boost instructions 12V 24V output indicator flashing 1 Weak charging connectors 2 Defective AC charger 3 Reverse charged protection after jumpstarted ...

Reviews: