background image

 

 

TROUBLE SHOOTING GUIDE: 

 

NOTE:

 Do not start vehicle until you check all connections. Make sure correct positive and negative polarity 

connections are achieved when using manual voltage selection for 12V or 24V to avoid damage to unit and/or vehicle 
battery. 

 

Trouble 

Cause 

Solution 

Vehicle does not 
start 

1. Bad clamp connection due to loose 
clamp installation. 
2. Incorrect polarity connection during 
automatic voltage detection. 12V/24V 
LED output indicators flashing & buzzing. 
3. Very low vehicle battery charge. 
4. Low Jump starter charge. 
5. Vehicle battery defective. 
6. Require higher starting current than 
provide by this unit. 
7. Vehicle electrical system faulty. 
8. Wrong manual voltage selected when 
battery is severely discharged. 

1. STOP! Carefully disconnect and reconnect the 
Jump starter booster clamps to the proper battery 
polarity to achieve full connections for positive & 
negative polarity. 
2. STOP! Carefully disconnect and reconnect the 
Jump starter booster clamps to the proper 
positive and negative vehicle battery polarity. 
3. Maintain Jump starter connection to the vehicle 
depleted battery. Wait 3-4 minutes before 
attempting to start vehicle again. 
4. Recharge the Jump starter to full charge or at 
least 50% of charge status. 
5. Replace with new battery. 
6. This unit will not start vehicle. Disconnect 
clamps and use Jump starter with higher starting 
current. 
7. Have your vehicle alternator/starter/battery 
checked by a professional for repair. 
8. Ensure to verify the correct battery voltage 
from the vehicle's owner manual and follow 
jumpstarting/battery boost instructions. 

12V/24V output 
indicator flashing 

1. Weak charging connectors. 
2. Defective AC charger. 
3. Reverse charged protection after 
jumpstarted vehicle. 
4. Vehicle battery defective & will not be 
charged with this unit. 

1. Insert AC charger plug to full contact into DC 
charger port. 
2. Replace with new AC charger. 
3. Immediately disconnect Jump starter clamps 
from vehicle battery connections. 
4. Replace with new battery. 

12V/24V output 
indicator flashing & 
buzzer during 
autovoltage 
connection  

1. Incorrect polarity connection during 
automatic voltage detection & short 
circuit protection activated. 

1. STOP! Carefully disconnect and reconnect the 
Jump starter booster clamps to the proper 
positive & negative vehicle battery polarity. 

Red LED (25%) 
flashing 

1. Low voltage protection. 

1. DO not use unit to jumpstart vehicle. Charge 
Jump starter immediately to at least 50% 
charging level. 

Red LED (25%) 
flashing & buzzer 

1. Over temperature protection. Jump 
starter exceeded 140° F operational 
temperature. 

1. Do not use Jump starter at existing 
temperature. Place unit in a well ventilated area 
to cool the battery. 

12V or 24V LED  
light stays 
illuminated after 
jumpstarted vehicle 

1. Normal operation. 

1. Press 12V or 24V output button until they turn 
off. 

 

 

                                         1-800-345-4545   jegs.com

 

Summary of Contents for 81952

Page 1: ... battery being jumped when making final connection Working around lead acid batteries may be dangerous Lead acid batteries generate explosive gases during normal charging and jump starting operations All lead acid batteries car truck boat produce hydrogen gas which may violently explode in the presence of fire or sparks DO NOT smoke use matches lighters or open flame near batteries DO NOT operate ...

Page 2: ...iece of metal to prevent short circuits and arching Avoid dropping metal tools onto vehicle battery It might spark or short circuit battery or other electrical parts that may cause short circuits or explosion Keep battery terminals clean Be careful to keep corrosion from coming in contact with eyes When using the 120V AC charger pull on the plug and never pull on the cord when disconnecting DO NOT...

Page 3: ... into the jump starter charging port 4 2 Insert the 120V AC charger transformer plug into a 120V AC receptacle 5 3 Fully charge the unit according to the following Initial first time charge charge until LED charge status lights turn off Recharge or between each use 6 to 8 hours 4 Charging LEDS will turn off once 100 status is achieved Press power push button to verify 100 charging status When char...

Page 4: ... possible Do not clamp directly to carburetor fuel lines or non grounded sheet metal body parts c See Jump Starting Battery Boost step 7 to continue Positive Grounded System a Securely connect the Negative Black clamp to the Negative NEG N ungrounded terminal of the vehicle battery b Securely connect the Positive Red clamp to the vehicle chassis engine block or a nonmoving grounded metal part of t...

Page 5: ...ower off the light press hold the power push button until lights turn off NOTE LED light emergency flasher SOS functions will operate in sequence to each other The lighting mode will depend on the prior last operating function selected User may have to cycle between modes in order to achieve the proper lighting function USB POWERED DEVICES 1 Prior to connecting the device to the unit s USB port ma...

Page 6: ...amps and use Jump starter with higher starting current 7 Have your vehicle alternator starter battery checked by a professional for repair 8 Ensure to verify the correct battery voltage from the vehicle s owner manual and follow jumpstarting battery boost instructions 12V 24V output indicator flashing 1 Weak charging connectors 2 Defective AC charger 3 Reverse charged protection after jumpstarted ...

Reviews: