11
5.1.5 Controls for MIG welding
5.1.5.1 Switch the machine on using the main power switch (10). Wait 5 seconds for the digital control program to load up.
Press the Left button (2) to mode section and select the mode by Left knob (1), press the Left knob (1) to confirm the
selection.
5.1.5.2The multifunction digital display will show two numbers. On the left is the preset welding voltage, on the right is
the preset wire feeding speed. These values are adjusted by rotating the Right knob (3). Because of the synergic digital
programming, both the voltage and the wire speed will adjust together.
5.1.5.3 To adjust the voltage independently, Rotate Left
Knob (1) to adjust the welding voltage
. This will change and give
the display screen as below.
Then use the Left knob
(1) to
adjust the welding voltage
‐
5~+5V
from the standard synergic
setting. This will not change the
wire speed. It is recommended for
ease of use that the wire feed
target speed is adjusted first and
then the voltage setting fine
‐
tuned if necessary. Refer to the
Welding Settings Quick Reference
Chart on page 21 and inside the
wire feed door for recommended
common settings.
Preset welding voltage
Wire speed
‐
5v~+5v