6
3.MAIN PARAMETER
Note : The welding duty cycle is the percentage of actual continuous welding time that can occur in a ten minute
cycle. For example:
15% at 200amps
‐
this means the welder can weld continuously at 200 amps for 1.5 minutes and
then the unit will need to be rested for 8.5 minutes.
The duty cycle can be affected by the environment in which the welder is used. In areas with temperatures exceeding
40
℃
, the duty cycle will be less than stated. In areas less than 40
℃
, higher duty cycles have been obtained
All tests on duty cycles have been carried out at 40
℃
with a 50%. So in practical working conditions the duty cycles will be
much greater than those stated above.
TYPE
BLUEARC
‐
200MSTI
Power supply voltage (V)
single
‐
phase
220V
15%
Input current (A)
36
Power supply capacity (KVA)
8
Current adjustment range (A)
50
~
200
Output voltage (V)
15
~
24
Rated output current (A)
200
Rated output voltage (V)
24
Rated duty cycle (%)
30
Power factor
0.75
Efficiency (%)
85
Wire feeder type
External/Internal
Post
‐
flow time (s)
1
Welding wire diameter (mm)
0.6/0.8/1.0
Machine size (mm)
480×310×430
Machine weight (kg)
17
Plate thickness (mm)
≥
0.8
Insulation class
F
Protection class
IP21S