12
JREMO 6K
Industrial radio remote controller
JREMO 6K
Industrial radio remote controller
CHAPTER 3. INSTALLATION & FUNCTION SETTING
3-3-2. INSTALLATION SEQUENCE
A. Power off equipment(ex. crane).
B. Use with the Fixing Plate provided together with Rx for sure installation
for absorbing and preventing vibration, shock, etc possibly causing upon
operation.
C. If available install RX to the position where the cable gland faces to the
downward direction, and do not put it to the upward way.
D. Connect only main power (wire no. 1 & 2) and main relay (EMS) ON (wire
no. 3 & 4) wires to the mating terminal of equipment.
E. At Tx twist up the red EMS button and push any button town and find if
the Rx Lamp is ON.
F. If it is necessary for confirming functions of each output relay of RX then
open the upper case of RX and find if they are correct functioning both
by hearing clicking sound and/or by looking led signaling at each related
relay(s). When all are o.k. then
G. Off the Rx power and push down red EMS button of Tx.
H. After off the power of Rx & Tx, connect all the remained functional each
wire of Rx to a mating terminal of equipment(ex. crane).
1. Confirm both circuit diagram of receiver and equipment(ex. crane)
are in sequence and connected correctly.
2. Confirm ground is O. K.
3. Check and confirm again power source.
F. Switch on receiver power by setting to remote at the selector switch
(manual/remote) if selector s/w is installed. If selector switch is not used
and connected the power line directly to the main, then the receiver
power is automatically on upon connected.
G. Check functions by using of Tx (Transmitter) as following :
1. Twisting up the EMS button and do as START ON Function.
2. And, confirm if the Tx (Receiver) MAIN Lamp is on.
H. Press each function button of transmitter and confirm all the related
functions are in normal.
3-4 HOW TO START
For the safety and secure operation
JREMO
series has adopted several
types of start functions as following to achieve enhanced safety :
■ Main ON Function
Standard Preset : EMS UP ⇨ Any button, Main ON
Optional Preset : EMS UP ⇨ Start P/B, Main ON