CHAPTER 4. MAINTENANCE
4-1 STANDARD OPERATION
A. Twist up the EMS button of Tx and do as START ON function procedure
preset and find the Rx Main Lamp ON. During normal operation see if the
Tx led shows Green light which is normal, and if the battery power of Tx
goes weak then the Tx led light will turn to red and green by turns, and it
still runs normally for some time. When it comes stop the operation be-
fore any abnormal functions such as delay responses, intermitting runs,
no stops, etc during working with both red and green light signalling.
B. Press down the EMS button when every normal operation finished and/
or in any emergency situation might occur do the same at once.
C. In case not in use for a long-term operation, take off all the batteries
from tx for avoiding of any contamination and/or unnecessary consump-
tion of battery power.
CHAPTER 4. MAINTENANCE
4-2 FUSES
A. A replaceable fuse is put inside the fuse column.
B. For replacement of fuse, use a flathead screwdriver or by hand to push
down head of the fuse cap by rotating 90°anticlockwise to open the cap.
C. Replace with a new fuse and close the cap in opposite procedure.
Fuse Cap
FUSE CAPACITY
AC Board
DC Board
POWER(F1) :
1A
5A
MAIN (F2) :
10A
20A