14
JREMO 6K
Industrial radio remote controller
JREMO 6K
Industrial radio remote controller
CHAPTER 5. TROUBLESHOOTING
5-1 SELF DIAGNOSIS (LED SIGNAL ERROR MESSAGE)
JEICO
remote controllers have a renewed method of self diagnostic trou-
bleshooting against so much complicated and riddled electronic struc-
tures, and yet it is easy to check and find causes and measures for any
malfunctions may occur.
JEICO
takes a type of Led signaling error message
for better, quick restoration in normal even at site.
CHAPTER 5. TROUBLESHOOTING
5-2 LED Diagnosis
Causes
LED Signals
Measures
Transmitter
(TX)
EMS Button not up
Red Light
Pull up EMS Button
Push Button defect
Red Flash
Replace with new button(s)
Encoder Module defect No Signal
Replace with a new module
Batteries Consumed
No Signal
Replace with new batteries
Low Power
Red & Green
Flashes
Replace with new batteries
Receiver
(RX)
Decoder defect
Lamp Off
Replace with a new Rx/Rf
Wrong Power Source
Lamp Off
Replace Fuses and/or
Replace Relay Board
Connect Right Power
Main Relay defect
Lamp Off
Replace Main Relay
Rx-Rf COPY position
Lamp Off
Set to RUN position
Main Power Off
Lamp Off
Engage Main Power