ERROR CODES
ERROR
CODE
DESCRIPTION
PROBABLE CAUSE
SHORTED .
THERMOCOUPLE .
OR .DEFECTIVE . .
HEATER .PLATES
Occurs .if .the .thermocouple .wires .are .shorted .or .the .heater .plates .are .
defective .causing .Infinity .to .achieve .a .HEAT .RATE .of .less .than .6% .of .the .
maximum .attainable .HEAT .RATE .with .full .power .applied .to .the .heater .
plates .for .5 .minutes . . .This .error .will .also .occur .if .a .program .is .running .
and .the .door .is .kept .open .for .more .than .5 .minutes .or .the .triac .or .the .
Main .PC .board .developed .a .problem .during .a .burnout .process .
Er .6
THERMAL .
RUNAWAY
Er .7
INVALID .ENTRY .
ERROR .WHILE .A .
PROGRAM .IS .
RUNNING
Flashing .
99:99 .
when .
NIGHT .
TIME .
(DELAY .
START) .is .
pressed .
during .a .
program
Occurs .when .the .HEAT .RATE .in .STAGE .2, .3 .or .4 .is .set .to .“COOL” .but .
the .corresponding .TEMP .is .entered .to .heat .to .a .higher .temperature .
than .the .previous .stage .
Occurs .when .the .temperature .has .exceeded .2015
°
F .(1102
°
C) .for .1 .
minute .if .the .highest .temperature .programmed .was .less .than .2000
°
F .
(1093
°
C) . . .This .also .occurs .when .the .temperature .has .exceeded .
2050
°
F .(1121
°
C) .for .1 .minute .if .the .highest .temperature .programmed .
was .2000
°
F .(1093
°
C) .or .higher .