15
Use the Menu Previous / Next buttons to select the LINK MODE option from the
SETTINGS menu.
Use the Up/Down buttons to select RECEIVE 1C (slave unit) or SEND (master
unit).
Press the Enter button to store the link setting, SET is displayed.
The machine should be set to SEND only if it is running as the master. If running
as a slave, stand-alone or DMX controlled it should be set to RECEIVE 1C. If a
machine set to SEND is connected to an active DMX system, the DMX will be
corrupted causing flickering of lights and other strange symptoms.
Priming th e machine
Upon first use of the machine or if the machine runs out of fluid it will
automatically shut down and display FLUID OUT on the display to prevent
damage to the pump. To suck the new fluid back into the machine and reset the
FLUID OUT error, replace/refill the low-fog fluid reservoir and use the prime
function – just press the Prime button on the fast access keypad on the rear of
the machine.
Alternatively, you can start Prime from the digital remote panel:
Use the Menu Previous / Next buttons to select the PRIME option from the
SETTINGS menu.
Use the Up/Down buttons to change the option to YES.
Press the Enter button to start the priming function.
The pump will operate at full power for a short time to purge air from the pipes
inside the unit.
To exit this menu if you decide not to activate the Prime function, select NO and
press ENTER.
Res etti ng options to factory setti ngs
The factory settings configure a standard mode of operation for the machine.
Use the Menu Previous / Next buttons to select the RESET option from the
SETTINGS menu.
Use the Up/Down buttons to change the option to YES.
Press the Enter button to reset all options.
To exit this menu if you decide not to reset the options, select NO and press
Enter.