The
has the ability to connect machines together using a Din lead
and then operating all of the machines with one controller. This is ideal when
there is a need for lots of smoke and there is no DMX to operate the machines.
Simply remove the controllers from all but one of the machines and then connect
a Din lead (5 pin) from the slave socket of the first machine (the one with the
controller) to the next machine’s remote socket, and then from that machine’s
slave to the next machine’s remote socket. This can be done from two up to ten
machines maximum. All of the machines will operate with the same output and
timer settings as the first machine.
ZR12-AL
Pin 1 - NA
Pin 2 - Gnd
Pin 3 - NA
Pin 4 - NA
Pin 5 - 0 - 10v
Wiring of Din
PAGE 8
MARTIN MANUFACTURING (UK) PLC
Using The Analogue Link
Master Machine
Link Cable From Master to Slave
Slave Socket
Remote Socket
Slave Machine
ZR12-AL USER GUIDE
Getting Started
•
•
•
•
Once you have selected the best position for the
you can begin to
use the machine. First check the power supply you have is correct for the
machine, if it is you can connect to the power supply and switch the mains
switch on at the rear of the machine. This will light when switched on, now
de-press the grey “stand-by” button, the machine will now heat up which
takes around 7 - 8 minutes. While it heats up you should check the level in
the fluid container, the container can hold up to 2.5 litres of fluid.
NOTE! Do not allow the
to run out of fluid. Serious damage may
occur if the machine is operated when no fluid is connected.
When the machine has reached working temperature the green “ready” LED
will light on the top of the machine and the machine can now be operated.
Check the “output” knob is turned fully clockwise (maximum) and press and
hold the red “fog” button. The fluid pump will start operating and if the
machine has a new container of fluid the fluid will take a few seconds to
reach the pump. When the pump has primed smoke will be visible. The output
can now be set to the desired level by turning the “output” knob. The timer
may be activated or you can simply use the “FOG” button when smoke is
required.
Once you have finished using the machine you should de-press the “stand-
by” button and then turn the mains switch off. If any problems occur when
operating the
please refer to the trouble shooting guide..