Installation and Operating Instructions ECOVARIO®114 D
12
Subject to change without notice!
4
Technical Data
4.1
Rated data of the power stage
Table 4.2: Rated data of the power supply, DC supply
Symb. Rated data
MAC2 – 2-phase AC servo motor
MAC3 – 3-phase AC servo motor
Unit
ECOVARIO® 114 D x-x x-xxx xxx
MAC2
MAC3
DC supply
4)
U
NDC
Rated supply voltage at DC input connector X4
V
DC
70 (24 ... 80)
P
N
Rated installed load
W
960
P
VN
Rated losses
5)
W
t.b.d.
Losses if diverging from nominal load: P
V
= P
V0
+ P
VI
P
V0
Basic losses
W
t.b.d.
P
VI/IO
Current-dependent losses per A
W/A
t.b.d.
U
O
Rated output voltage
1)
V
DC
60
V
AC
45
I
ON
Rated output current
6)
per axis
A
DC
10
A
RMS
7.1
P
ON DC
Rated output power with DC motor
1)
per axis
W
650
P
ON AC
Rated output power with AC motor
1)
per axis
W
477
545
I
OP
Peak output current
2)
per axis
A
DC
20
A
RMS
14
U
BUSN
Rated DC link voltage
V
DC
60
U
BUSP
max. DC link voltage
V
DC
70
U
P
Overvoltage trip
V
DC
90
C
L
DC link capacity
µF
660
E
N-P
Regenerable capacity
Ws
0.5
For an explanation of the footnotes see next page.
4.2
General technical data
Table 4.3: General technical data, control signals
No.
Control signal
Unit
1
24 V supply (current draw without outputs)
V
24 ±10 %
A
0.8
10
Digital control signal inputs
V
LOW 0 – 7, HIGH 12 – 36
mA
10 (at 24 V)
4
Digital control signal outputs
V
24
A
0,5