5.1.3 Assembly
Basically, ECOVARIO®114 D is intended for vertical mounting (motor connector X5A, X5B on the bot-
tom). In this mounting position devices can be operated with natural convection at ambient temperatures
of up to 40°C. Th e ECOVARIO 114 D with STO function has to be mounted in a cabinet which conforms
to protection class IP54 (or in a comparable environment).
If the ECOVARIO®114D is mounted in a cabinet cable clamps and side metal sheets assure that the connec-
ting cables are laid EMC conform by connecting the cable shield extensively to chassis earth.
Th e shields with cable clamps shown in fi g. 5.3 are available as accessories (see table 9.1). Th e lower shield
is mandatory, the upper shield normally is only necassary if a ballast circuit is connected to X4A and/or
X4B. It is important that the air fl ow is not disturbed by components above or below the servo amplifi ers.
Th e distance between the servo amplifers has to be at least 3 mm. In order to achieve a good access to the
connectors at the bottom of the device the distance can be increased.
Fig. 5.2: Mounting dimensions cabinet, width [mm]
Kabelkanal
Kabelkanal
245
60
60
45
ECOV
ARIO
1
14D
®
ECOV
ARIO
1
14D
®
245
20
60
ECOV
ARIO
1
14D
®
Kabelkanal
Cable conduct
Cable conduct
Cable conduct