Learning to Use the Lean Clean 360 Cleaning System
17
Choosing a Location
Locate the Lean Clean on a smooth level floor capable of holding 2,350
pounds (wet weight) and the weight of any accessory equipment such as the
optional oil separator or drain station.
The Lean Clean footprint is 3 feet by 5 feet, but sufficient room should be left
for operation and maintenance and optional equipment.
If the floor is not level, use shims and a level to level the Lean Clean. A level
installation promotes vibration-free operation, reduces strain on the machine
framework, and promotes proper overflow drainage and liquid level sensing.
The selected location should be clean, dry, and provide efficient work flow
within the manufacturing environment. The location temperature range
should be 55
–
120°F.
Consider the following location requirements: access to utilities, drains, and
cleaning chemistry supply. Utility requirements include electricity supply,
compressed air, and process water.
Caution
—
If hot, strong cleaning chemistries contact skin or eyes, bodily injury
can result. To minimize harm in the event of accidental contact with hot cleaning
chemistries, users should locate the Lean Clean in an area with emergency eye
wash and showers, or install an emergency eye wash and showers in the area
where the Lean Clean is installed.
Post Installation Checks
After positioning and leveling the machine, open the process chamber door
and inspect the alignment between the rotating drum support rings and the
flanged rollers. The support rings should be in the flanges. (Rough shipping
and handling can cause the rotating drum to jump out of the flanges.)
Caution
—
If the rotating drum support rings are not in the flanges and you start
the machine, equipment damage can result. To avoid equipment damage, visually
inspect the support rings on the rotation drum and ensure they are in the flanges.
Ensure there are no foreign objects in the wash tank and rinse tank. Verify
that the chip baskets are in place, the wash and rinse water inline filters are
installed, and that the level and temperature probes
and dryer hose are not damaged.