28
Learning to Use the Lean Clean 360 Cleaning System
Cold Startup
Follow these steps to complete a cold startup:
1.
Close the drain lines for the wash and rinse tanks.
2.
Add the washing chemistry to the wash tank per the chemistry
manufacturer’s recomme
ndations. The wash tank holds 55 gallons. If
you are using the oil separator, consider its 15-gallon volume in the
chemistry calculation.
3.
If you are using rinse chemistry, add it to the rinse tank per the
chemistry manufacturer’s recomme
ndation. The rinse tank holds 55
gallons.
4.
Using the manual fill valves, fill the wash and rinse tanks to 4-inches
below the top.
5.
If you are using an oil separator, you can prime it with 15 gallons of
water or allow the wash tank liquid level controls to automatically fill
the oil separator o
nce the oil separator’s pump is started
.
6.
Check the wash and rinse inline filters to ensure they are installed and
sufficiently clean following the procedure described on page 47.
7.
Power up the system by pulling out the
Emergency Stop
button pressing
the yellow
Power
button on the control panel. The tanks heaters will
begin to heat the solutions in the tank.
8.
After the tanks reach the operating temperature, use the operator
interface to place the machine into manual mode. Close the washing
chamber door, and open the wash chamber main drain.
9.
Set diverter to the wash tank position. Open the bleed valve on the
top of the wash tank filter housing and start the wash tank pump.
When water flows from the bleed line, close the bleed valve and stop
the pump.