7
Electrical Requirements - Canada Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
■
When a 4-wire, single phase 250 volt, 60 Hz., AC only
electrical supply is available, a 40-amp minimum circuit
protection is required on 30" (76.2 cm) and 36" (91.4 cm)
ranges and a 50-amp minimum circuit protections is required
on 48" (121.9 cm) ranges, fused on both sides of the line.
■
A time-delay fuse or circuit breaker is recommended.
■
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s final location.
■
Do not use an extension cord.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 - latest edition or CAN/CGA B149 -
latest edition.
IMPORTANT: Range cooktop must be connected to a regulated
gas supply.
IMPORTANT: Leak testing of the range cooktop must be
conducted according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This range is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
■
This range is factory set for use with Natural gas. The model/
serial rating plate located under the console on the right-hand
side has information on the types of gas that can be used. If
the types of gas listed do not include the type of gas
available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the range cooktop from the
gas specified on the model/serial rating plate for use with a
different gas without consulting the serving gas supplier. To
convert to LP gas, use the LP gas conversion kit provided with
your range and see the “Gas Conversions” section. The parts for
this kit are in the literature package supplied with the range.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Summary of Contents for 30" (76.2 cm) Cooktop
Page 25: ...25 Notes...