background image

13

Base Grille Water Filtration System

Model P1WG2L/P2RFWG2 Capacity 200 Gallons (757 Liters)

Model P1WG2/P2RFWG2 Capacity 200 Gallons (757 Liters)

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). 
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.

Use replacement filter P2RFWG2, part #4396841. 
2008 suggested retail price of $39.99 U.S.A./$54.95 Canada. 
Prices are subject to change without notice.
Model P1WG2L/P1WG2: Style 1 – When the filter indicator 
reads 10%, order a new filter. When the indicator reads 0%, it is 
recommended that you replace the filter. 
Style 2 – When the filter indicator changes from green to yellow, 
order a new filter. When the indicator changes from yellow to red, 
it is recommended that you replace the filter. 
Style 3 – When the water filter status display changes from 
“GOOD” to “ORDER,” order a new filter. When the filter indicator 
reads “REPLACE,” it is recommended that you replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If 
the filter indicator light is yellow, order a new filter. If the filter 
indicator light is red, it is recommended that you replace the filter.
Change the water filter cartridge every 6 months. If the water 
flow to the water dispenser or ice maker decreases noticeably 
before 6 months have passed, replace the water filter cartridge 
more often. 

These contaminants are not necessarily in your water supply. 
While testing was performed under standard laboratory 
conditions, actual performance may vary.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after the 
system.

Refer to the “Warranty” section for the Manufacturer’s name, 
address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI 
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate 
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, 
Mercury, Benzene, Toxaphene, and O-dichlorobenzene. 

Substance Reduction
Aesthetic Effects

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average % 
Reduction

Chlorine Taste/Odor
Particulate Class I

*

50% reduction
85% reduction

1.909 mg/L
5166666 #/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.05 mg/L
4200 #/mL

**

<0.05 mg/L
1900 #/mL

>97.4
>99.9

>97.4
>99.9

Contaminant
Reduction

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average % 
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

143.33 ug/L
150 ug/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

1.0 ug/L
1.0 ug/L

1.0 ug/L
1.0 ug/L

>99.3
>99.3

>99.3
99.3

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.00646 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.3 ug/L
0.8 ug/L

0.0002 mg/L
0.0004 mg/L

94.8
88.5

96.4
94.9

Benzene

0.005 mg/L

0.015 mg/L

0.015 mg/L ± 10%

0.5 ug/L

0.0005 mg/L

>96.7

>96.7

O-Dichlorobenzene

0.6 mg/L

1.83333 mg/L

1.8 mg/L ± 10%

160 ug/L

0.005 mg/L

91.1

96.5

Toxaphene

0.003 mg/L

0.016 mg/L

0.015 mg/L ± 10%

1 ug/L

0.001 mg/L

>93.8

>93.8

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi

*

**

Class I particle size: >0.5 um to <1 um 
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

® NSF is a registered trademark of NSF International.

Summary of Contents for JCD2591WES00

Page 1: ...WATER FILTER CERTIFICATIONS 9 PERFORMANCE DATA SHEETS 10 WARRANTY 14 S CURIT DU R FRIG RATEUR 15 UTILISATION DU R FRIG RATEUR 16 ENTRETIEN DU R FRIG RATEUR 20 D PANNAGE 21 ACCESSOIRES 23 FEUILLES DE D...

Page 2: ...erous even if they will sit for just a few days If you are getting rid of your old refrigerator please follow these instructions to help prevent accidents Before You Throw Away Your Old Refrigerator o...

Page 3: ...l Control Panel Features Temp Mode Press the C button to select either Celsius or Fahrenheit temperature displays Max Cold Use Max Cold to speed cooling when large grocery loads are added Max Cold set...

Page 4: ...nds To switch from cups to liters press and hold the buttons for another 3 seconds To switch back to ounces repeat the process a third time 2 Remove the glass to stop dispensing The Ice Dispenser Ice...

Page 5: ...ontrol to the OFF right position when removing the storage bin The sensor cover flipper door on the left wall of the freezer stops the ice maker from producing ice if the door is open or the storage b...

Page 6: ...with one of the same size shape and wattage 4 Replace light shield when applicable 5 Plug in refrigerator or reconnect power TROUBLESHOOTING First try the solutions suggested here or visit our website...

Page 7: ...for ice production to begin Allow 3 days after ice production begins to completely fill ice container Does the ice maker mold have water in it or has no ice been produced Make sure your refrigerator...

Page 8: ...e it is used Is the refrigerator connected to a cold water line with water pressure of at least 30 psi 207 kPa The water pressure to the home determines the flow from the dispenser Is there a water fi...

Page 9: ...9 WATER FILTER CERTIFICATIONS...

Page 10: ...or cold water use only Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Refer to the Warranty section for the Manuf...

Page 11: ...r use only Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Refer to the Warranty section for the Manufacturer s na...

Page 12: ...y While testing was performed under standard laboratory conditions actual performance may vary The product is for cold water use only Do not use with water that is microbiologically unsafe or of unkno...

Page 13: ...y While testing was performed under standard laboratory conditions actual performance may vary The product is for cold water use only Do not use with water that is microbiologically unsafe or of unkno...

Page 14: ...ratches dents chips or other damage to the finish of your major appliance unless such damage results from defects in materials or workmanship and is reported to Jenn Air within 30 days from the date o...

Page 15: ...es de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous e...

Page 16: ...oid que le r glage recommand ne refroidira pas les compartiments plus rapidement Mise en marche du r frig rateur Si le r frig rateur n est pas allum appuyer sur ON OFF marche arr t pour mettre en marc...

Page 17: ...s 24 heures ou lorsque la fonction Max Cold est manuellement d sactiv e les valeurs de r glage reviendront leur r glage ant rieur Appuyer sur MAX COLD pour s lectionner ce mode La fonction Max Cold r...

Page 18: ...ibuteur Accorder 24 heures pour que le r frig rateur se refroidisse et refroidisse l eau Accorder 24 heures pour produire la premi re quantit de gla ons Jeter les trois premi res quantit s de gla ons...

Page 19: ...e Lorsque le distributeur est verrouill le t moin lumineux passe au rouge pendant quelques secondes puis s teint Appuyer nouveau sur LOCKOUT pour d verrouiller le distributeur Lorsque le distributeur...

Page 20: ...ig ration et de cong lation se d givrent automatiquement Toutefois nettoyer les deux sections environ une fois par mois pour viter une accumulation d odeurs Essuyer les renversements imm diatement IMP...

Page 21: ...tion la plus froide ne refroidira aucun des compartiments plus rapidement Le moteur semble trop tourner Il se peut que votre nouveau r frig rateur fonctionne plus longtemps que l ancien en raison du c...

Page 22: ...install e La temp rature du cong lateur est elle assez froide pour produire de la glace Attendre 24 heures apr s le raccordement de la machine gla ons avant qu elle produise des gla ons Pr voir un d...

Page 23: ...correctement V rifier ce qui suit La porte du cong lateur est elle compl tement ferm e La valve du robinet d arriv e d eau est elle ferm e mal install e ou obstru e La conduite d eau est elle connect...

Page 24: ...le rendement r el peut varier Le produit doit tre utilis pour l eau froide seulement Ne pas utiliser pour le filtrage d une eau microbiologiquement pollu e ou de qualit inconnue en l absence d un disp...

Page 25: ...peut varier Le produit doit tre utilis pour l eau froide seulement Ne pas utiliser pour le filtrage d une eau microbiologiquement pollu e ou de qualit inconnue en l absence d un dispositif de d sinfe...

Page 26: ...otre approvisionnement d eau M me si le test a t effectu dans des conditions de laboratoires standard le rendement r el peut varier Le produit doit tre utilis pour l eau froide seulement Ne pas utilis...

Page 27: ...votre approvisionnement d eau M me si le test a t effectu dans des conditions de laboratoires standard le rendement r el peut varier Le produit doit tre utilis pour l eau froide seulement Ne pas utili...

Page 28: ...ation et ne soient signal s Jenn Air dans les 30 jours suivant la date d achat 6 Toute perte d aliments ou de m dicaments due une d faillance du r frig rateur ou du cong lateur 7 Le ramassage et la li...

Reviews: