background image

CONNECTING THE RANGE (cont.)

Gas Supply

Installation of this range must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1-latest edition. In
Canada the range must be installed in accordance with the current CGA
Standard CAN/CGA-B149 - Installation Codes for Gas Burning Appliances and
Equipment and/or local codes.

A QUALIFIED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST
MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance
shall be conducted by the installer according to the instructions
given in step 6.

Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the supply line shut-off valve and the range. Include gas
fittings and joints in the range if connections were disturbed during installation.
Check for leaks! Bubbles appearing around fittings and connections will
indicate a leak. If a leak appears, turn off supply line gas shut-off valve, tighten
connections, turn on the supply line gas shut off valve, and retest for leaks.

CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME. WHEN LEAK
CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.

NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL GAS SERVICE REGULATOR.
INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF
14 INCHES WATER COLUMN (0.5 POUNDS PER SQUARE INCH (P.S.I.) LIQUEFIED
PETROLEUM (L.P.)/PROPANE GAS SUPPLY LINE MUST HAVE A L.P. GAS
PRESSURE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE
REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 P.S.I.). INLET
PRESSURES IN EXCESS OF 0.5 P.S.I. CAN DAMAGE THE APPLIANCE PRESSURE
REGULATOR AND OTHER GAS COMPONENTS IN THIS APPLIANCE AND CAN
RESULT IN A GAS LEAK.

Gas supply pressure for testing regulator must be at least 1” water
column pressure above manifold pressure shown on serial plate.

GAS SUPPLY CONNECTION

Follow these procedures to remove appliance for servicing:

1. Slide range forward to disengage range from the anti-tip bracket.
2. Shut off gas supply to appliance.
3. Disconnect electrical supply to appliance, if equipped.
4. Disconnect gas supply tubing to appliance.
5. Reverse procedure to reinstall. If gas line has been disconnected,

check for gas leaks after reconnection.

6. To prevent range from accidentally tipping, range must be secured to the floor by sliding rear leveling leg into the anti-tip bracket.

NOTE:

A qualified servicer should disconnect and reconnect the gas supply. The servicer MUST follow installation instructions provided with the gas appliance connector

and the warning label attached to the connector.

HOW TO REMOVE RANGE FOR SERVICING

SERVICE-PARTS INFORMATION

When your range requires service or replacement parts, contact your dealer or authorized service agency. Please give the complete model and serial number of the
range which is located on flip-up plate at the rear of upper left-hand corner or center of backguard.

Your range may not be equipped with some of the features referred to in this manual.

all new branch circuits, mobile homes and when local codes prohibit grounding through
the neutral. For a 3-wire cord replacement, service kit P/N 74011285 must be used.

In The Commonwealth Of Massachusetts

This product must be installed by a licensed plumber or gas fitter when installed
within the Commonwealth of Massachusetts. A “T” handle type manual gas
valve must be installed in the gas supply line to this appliance. A flexible gas
connector, when used, must not exceed a length of three (3) feet / 36 inches.

Check Pressure of House Piping System

1. The appliance and its individual shutoff valve must be disconnected from

the gas supply piping system during any pressure testing of that system at
test pressures in excess of 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).

2. The appliance must be isolated from the gas supply piping system by

closing its individual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than 1/2
lbs./sq. in. (3.5 kPa) (13.8 in. water column).

A GAS SHUT-OFF VALVE SHOULD BE PUT IN AN ACCESSIBLE LOCATION IN THE
SUPPLY LINE AHEAD OF THE RANGE, FOR TURNING ON AND TURNING OFF GAS
SUPPLY. Range is to be connected to house piping with flexible metal connectors
for gas appliances. CONNECTOR NUTS MUST NOT BE CONNECTED DIRECTLY TO
PIPE THREADS. THE CONNECTORS MUST BE INSTALLED WITH ADAPTORS PROVIDED
WITH THE CONNECTOR.

The house piping and/or range connector used to connect the range to the main gas
supply must be clean, free of metal shavings, rust, dirt and liquids (oil or water). Dirt,
etc. in the supply lines can work its way into the range manifold and in turn cause
failure of the gas valves or controls and clog burners and/or pilot orifices.

Always use a new flexible connector. Do not use existing flexible connector.

Gas leaks may occur in your system and result in a dangerous situation. Gas

leaks may not be detected by smell alone. Gas suppliers recommend you

purchase and install an UL approved gas detector. Install and use in

accordance with manufacturer’s instructions.

NOTE:

It is recommended to use a CSA certified flexible connector no longer than 36” (91.4 cm) with a minimum BTU/HR rating of 88,200.

DISCONNECT ELECTRICAL SUPPLY BEFORE SERVICING
THE APPLIANCE.

W A R N I N G

W A R N I N G

Summary of Contents for JDS8850BDB

Page 1: ...avec l appareil INSTALADOR Deje estas instrucciones con el electrodom stico Jenn Air Dual Fuel Updraft Slide In Range Installation Instructions Instructions d installation Instrucciones de Instalaci...

Page 2: ...hown in steps 14 19 MOBILE HOMES The installation of a range designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 forme...

Page 3: ...ttached to the connector HOW TO REMOVE RANGE FOR SERVICING SERVICE PARTS INFORMATION When your range requires service or replacement parts contact your dealer or authorized service agency Please give...

Page 4: ...l alimentation est n cessaire conform ment aux codes locaux Il est possible d utiliser soit un conduit soit un cordon souple Avec un cordon souple pour cuisini res ne l utilisez qu avec des cosses fe...

Page 5: ...DER L ENTRETIEN RENSEIGNEMENTS SUR LES SERVICES ET LES PI CES Lorsque votre cuisini re a besoin d entretien ou de pi ces de rechange prenez contact avec votre d taillant ou agence de service autoris...

Page 6: ...e requiere una conexi n al suministro el ctrico de acuerdo con los c digos locales Se proporcionan provisiones para usar tanto un conducto fijo o un cord n flexible para la conexi n de la estufa Cuand...

Page 7: ...N DE LA ESTUFA PARA SERVICIO INFORMACI N SOBRE LOS REPUESTOS Cuando su estufa requiera reparaci n o el reemplazo de piezas p ngase en contacto con su distribuidor o agencia de servicio autorizado Por...

Page 8: ...rotected with fireproof materials in accordance with American National Standards National Fuel Gas Code or in mobile homes when they are protected with fireproof materials in accordance with the Feder...

Page 9: ...moins de 61 cm 24 po lorsque les armoires murales d une r sidence sont prot g es par des mat riaux ignifuges conform ment aux normes de l American National Standards National Fuel Gas Code Code nation...

Page 10: ...ttoyage normal Il peut se produire une d coloration ou une d stratification Pour viter tout risque de dommages nous vous recommandons d agrandir l ouverture de l armoire de jusqu 79 4 cm 31_ po au min...

Page 11: ...ersi n antes de realizar la instalaci n Puede encontrar el kit de instrucciones en el estante del regulador detr s del protector Cardboard Cross Support Support transversal en carton Soporte cruzado d...

Page 12: ...a todas las roscas Siempre sostenga el regulador en una posici n estable mientras conecta la tuber a de suministro 6 Check all gas connection joints and fittings for leaks with a non corrosive leak d...

Page 13: ...l suministro el ctrico 12 10 Gas gaz Gas Electric lectrique El ctrica Make sure flexible connector and electrical cord are not kinked Check leg position in ANTI TIP bracket V rifiez la position du pie...

Reviews: