NATURAL GAS TO PROPANE GAS (LP) CONVERSION INSTRUCTIONS
WARNING
TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS
Manifold - Propane Gas pressure required - 10
²
Water
Column.
Incoming Propane Gas pressure required to regulator -
11
²
- 14
²
Water Column.
Propane Gas conversion Orifice Hoods are supplied with
these models.
PROPANE CONVERSION
Propane conversion is to be performed by a JENN-AIR
AUTHORIZED SERVICE CONTRACTOR (or other
qualified agency) in accordance with the manufacturer’s
instructions and all codes and requirements of the
authority having jurisdiction. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for this conversion.
Natural gas supply line must have a natural gas service
regulator. Inlet pressure to this appliance should be
reduced to a maximum of 14 inches water column (0.5
pounds per square inch (P.S.I.) liquified petroleum
(L.P.)/propane gas supply line must have a L.P. gas
pressure regulator. Inlet pressure to this appliance
should be reduced to a maximum of 14 inches water
column (0.5 P.S.I.). Inlet pressures in excess of 0.5
P.S.I. can damage the appliance pressure regulator
and other gas components in this appliance and can
result in a gas leak.
WARNING
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION.
INCHES
BURNER
BTU/hr
DIAMETER
COLOR
Left Rear (LR)
8,000
.033
Zinc
Left Front (LF)
8,000
.033
Zinc
Right Rear (RR)
8,500
.035
Green
Right Front (RF)
8,500
.035
Green