 DETAILED PLANNING DIMENSIONS

2 of 2

8997AdZw217

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation Guide 

before

 

selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  
All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

15" MODULAR ELECTRIC GRIDDLE

JEF3115G – 15" x 5

13

32

" x 21"

OPENING/CLEARANCE DIMENSIONS

D*

G

E

A

B

B

I

K

J

H

C

e

F

Side

Cabinet

H

D*

G

E

A

B

B

I

K

J

H

C

e

F

Side

Cabinet

H

D*

G

E

A

B

B

I

K

J

H

C

e

F

Side

Cabinet

H

MODEL #

JEF3115G

in

cm

A

Width of combustible area above 
cooking surface (min.)

15

38.1

B

Width from cooktop to fixed wall or 
other combustible material (min.)

6

15.2

C

Width to outer edge of outlet (max.)

9

23.0

D*

Height to bottom of uncovered wood or  
metal cabinet above cooking surface (min.)

30

76.2

E

Height to bottom of uncovered wood or 
metal cabinet (min.)

18

45.7

F

Height to top edge of outlet (min.)

7

17.8

G

Depth of upper cabinet

13

33.0

H

Depth from cutout to wall (min.)

2

5

8

6.7

I

Width of cutout (recommended)

14

3

8

36.5

J

Depth of cutout (recommended)

20

3

8

51.8

K

Depth from cutout to front of countertop

2

5

16

5.9

e

Recommended electrical access location 

* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal 

cabinet is covered by not less than 

1

4

" (0.6 cm) flame retardant millboard 

covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) 
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

   If installing a hood or microwave hood combination above the cooktop, 

follow the hood or microwave hood combination instructions for 
dimensional clearances above the cooking surface.

FRONT VIEW

ELECTRICAL REQUIREMENTS

A 240 Volt, 60 Hz, AC only 15-amp fused, grounded electrical circuit is 
required. A time-delayed fuse or dedicated circuit is recommended.
A grounded 3-prong outlet should be located in the back of the cabinet. 
Do not use an extension cord.

LOCATION REQUIREMENTS

•   To ensure cooktop base clearance, cabinet side walls need to be wider 

than the cutout 

•  If cabinet has a drawer, allow a 5

1

2

" (14.0 cm) minimum clearance 

between countertop and top of drawer. 

TOP VIEW

SIDE VIEW