background image

3

Check the cooktop serial plate to see if the cooktop is

approved for installation in mobile homes and/or

recreational park trailers. Serial plate is located on the

bottom of the unit.

If approved, the following items are applicable:

Mobile Homes

The installation of a range designed for mobile home

installation must conform with the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part

3280 [formerly the Federal Standard for Mobile Home

Construction and Safety, Title 24 HUD, (Part 280)] or,

when such standard is not applicable, the Standard for

Manufactured Home Installations, ANSI A225.1/NFPA

501A, or with local codes.

In Canada the range must be installed in accordance with

the current CSA Standard C22.1 -- Canadian Electrical

Code Part 1 and Section Z240.4.1 -- Installation

Requirements for Gas Burning Appliances in Mobile

Homes (CSA Standard CAN/CSA -- Z240MH).

Recreational Park Trailers

The installation of a range designed for recreational park

trailers must conform with state or other codes or, in the

absence of such codes, with the Standard for

Recreational Park Trailers, ANSI A119.5-latest edition.

In Canada the range must be installed in accordance with

CAN/CSA -- Z240.6.2 -- Electrical Requirements for R.V.’s

(CSA Standard CAN/CSA -- Z240 RV Series) and Section

Z240.4.2 -- Installation Requirements for Propane

Appliances and Equipment in R.V.’s (CSA Standard

CAN/CSA -- Z240 RV Series).

Installation Of Appliance

The installation of this appliance must conform with local

codes or, in the absence of local codes, with the National

Fuel Gas Code, ANSI Z223.1--Latest Edition, or, in

Canada, CAN/CGA-B149 Installation Code, Latest

Edition.

This appliance, when installed, must be electrically

grounded in accordance with local codes or, in the

absence of local codes, with the National Electrical Code

ANSI/NFPA No. 70--Latest Edition, or, in Canada, current

CSA Standard C22.1 Canadian Electrical Code, Part 1.

In The Commonwealth Of Massachusetts

This product must be installed by a licensed plumber or

gas fitter when installed within the Commonwealth of

Massachusetts.

A “T” handle type manual gas valve must be installed in

the gas supply line to this appliance.

A flexible gas connector, when used, must not exceed a

length of three (3) feet / 36 inches.

All supply piping, except as noted, should use common

National Pipe Thread (N.P.T.). For all pipe connections

use an approved pipe joint compound resistant to the

action of LP gas.

CAUTION:

Warranty is void on Jenn--Air equipment

installed other than as recommended by manufacturer.

This appliance is designed for use with the appliance gas

pressure regulator supplied with this appliance. It must be

installed in the gas line ahead of the gas manifold

entrance. It is preset for use with natural gas and must be

converted, as described on pages 8 and 9, for use with

LP gas. (See figures 7 -- 12).

This appliance is designed to operate at a pressure of 5

inches of water column (36

models), 4 inches of water

column (30

models) on natural gas or, if converted for

use with LP gas (propane or butane), 10 inches water

column. Make sure this appliance is supplied with and

adjusted for the type of gas for which it is designed.

This appliance was adjusted at the factory for use with

natural gas. If, at any time, this appliance is to be used

with a different type of gas, all of the conversion

adjustments described on pages 8 and 9 must be made

by a qualified service technician before attempting to

operate the cooktop on that gas. Natural gas should be

supplied to the appliance pressure regulator at a line

pressure between 6 and 14 inches of water column or, if

converted for LP gas, between 11 and 14 inches.

If the line pressure supplying the appliance pressure

regulator exceeds 14

water column (any gas), an

external regulator must be installed in the gas line ahead

of the appliance regulator to reduce the pressure to no

more than 14

water column. Failure to do this can result

in malfunction and damage to the appliance.

WARNING

Insure this appliance is adjusted for the type of gas

supplied to it and that the gas supply pressure to the

appliance regulator is within the proper pressure range.

S

If no other appliance is to be installed in the cabinetry

below this unit, proceed as instructed under paragraph

1, page 4.

S

If this unit is to be installed over a Jenn--Air Model

JJW9530, JJW9130, JJW8530 or JJW8130 Series

Electric Wall Oven proceed as instructed under

paragraph 2, page 5.

NOTE:

In Canada, gas utilization codes prohibit use of

street elbows. Use standard pipe elbows and make

modifications to these instructions as necessary.

Summary of Contents for JGC1430

Page 1: ...IAL WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE NOTICE TO INSTALLER Leave these instructions with the applia...

Page 2: ...cut accurately to within 1 16 159 cm to ensure proper fit Important Preparation Suggestions 1 Chamfer all exposed edges of decorative laminate to prevent damage from chipping 2 Radius corners of cutou...

Page 3: ...r when used must not exceed a length of three 3 feet 36 inches All supply piping except as noted should use common National Pipe Thread N P T For all pipe connections use an approved pipe joint compou...

Page 4: ...threads Install a manual shut off valve in an accessible location in the gas line ahead of the appliance pressure regulator and external to this appliance for the purpose of turning on or shutting off...

Page 5: ...ion in the gas line ahead of the appliance regulator and external to the appliance for the purpose of turning on or shutting off gas to the appliance Make additional pipe connections as necessary ahea...

Page 6: ...fittings and connections will indicate a leak If a leak appears turn off supply line gas shut off valve tighten connections turn on the supply line gas shut off valve and retest for leaks Never test...

Page 7: ...e mounted in either a left or right adjacent cabinet a clearance hole as described above must be provided in the dividing wall between the cabinets Figure 4 page 5 illustrates a typical left side divi...

Page 8: ...ing 2 screws See figure 7 Step 3 Firmly press 9 32 or 7mm nut driver over the orifice spud figures 7 and 8 and loosen spud by turning counter clockwise Carefully lift nut driver out of burner throat O...

Page 9: ...ng screw clockwise until tight 5 7 in lbs max Do not over tighten 6 Replace rubber grommet and control knob 7 Repeat for remaining burners FIGURE 12 KNOB KNOB HOLE KNOB AND GROMMET REMOVED After adjus...

Page 10: ...liance is again converted for use with LP gas B INVERT CAP IN APPLIANCE PRESSURE REGULATOR See figure 11 With the appliance installed the appliance regulator should be located as shown in either figur...

Page 11: ...yellow tips or are hazy and otherwise appear to have insufficient air obtain the services of a qualified service technician Some yellow tipping on LP gas is normal Specified input rates are as shown i...

Page 12: ...TERTOP BURNER BOX HOLD DOWN SCREW HOLD DOWN BRACKET How To Remove Cooktop For Servicing Follow this procedure to remove the cooktop for servicing 1 Shut off gas supply to the cooktop 2 Disconnect elec...

Page 13: ...1430 y JGC1536 ADVERTENCIA ESPECIAL LA INSTALACI N EL AJUSTE LA ALTERACI N EL SERVICIO EL MANTENIMIENTO O EL USO INCORRECTOS DE LA ESTUFA PUEDEN CAUSAR LESIONES GRAVES O DA OS MATERIALES AVISO AL INST...

Page 14: ...n muy importantes Las dimensiones deben medirse y cortarse con precisi n a 1 16 0 159 cm para garantizar un ajuste correcto Sugerencias importantes de preparaci n 1 Alise todos los bordes expuestos de...

Page 15: ...le de gas no debe exceder una longitud de tres 3 pies o 36 pulgadas 91 4 cm Toda la tuber a de suministro excepto cuando se indica debe ser de tipo com n de rosca NPT National Pipe Thread Use en todas...

Page 16: ...co Haga las conexiones adicionales de la tuber a que sean necesarias antes de la v lvula de cierre a la fuente de suministro de gas Aseg rese de que todas las conexiones de uniones de la tuber a est n...

Page 17: ...ierre a la fuente de suministro de gas Aseg rese de que todas las conexiones de uni n de la tuber a est n firmemente ajustadas FIGURA 4 ILUSTRACI N DE LA TUBER A DE SUMINISTRO DE GAS HORNO DE PARED IN...

Page 18: ...riete las conexiones abra la v lvula de cierre de la tuber a de gas y vuelva a revisar las fugas Nunca revise las fugas de gas con una llama encendida Pruebas de presi n El electrodom stico debe aisla...

Page 19: ...adyacente a la derecha o a la izquierda deber proporcionarse un orificio como el descrito anteriormente en la pared divisoria entre los gabinetes La figura 4 de la p gina 5 ilustra una pared divisori...

Page 20: ...dola en sentido contrario al de las manecillas del reloj Levante con cuidado el destornillador fuera del cuello del quemador La copa de orificio deber estar atrapada en el destornillador Repita los pa...

Page 21: ...a ranura del tornillo de ajuste 5 Gire el tornillo de ajuste en el sentido de las manecillas del reloj hasta que est bien ajustado 5 7 pulgadas lbs m x No lo apriete demasiado 6 Coloque de nuevo la ar...

Page 22: ...ra uso futuro Se necesitar n si este aparato se convierte de nuevo para usarse con gas LP B INVIERTA LA TAPA DEL REGULADOR DE PRESI N Vea la figura 11 Despu s de instalar el electrodom stico el regula...

Page 23: ...la o est borrosa y por otra parte parece no tener suficiente aire consiga los servicios de un t cnico calificado Algunas puntas amarillas del gas LP son normales Las clasificaciones de entrada espec f...

Page 24: ...e para cocinar para darle servicio Siga este procedimiento para quitar la superficie para cocinar para darle servicio 1 Cierre el suministro de gas a la superficie para cocinar 2 Si corresponde descon...

Page 25: ...ISE R ALISATION DE LA MISE EN PLACE DU R GLAGE DE TOUTES MODIFICATIONS OU R PARATIONS OU DE L ENTRETIEN DE LA CUISINI RE OU SON USAGE INCORRECT PEUVENT ENTRA NER DES BLESSURES OU DES D G TS GRAVES DIM...

Page 26: ...upe effectu e 1 16 po 2 mm pr s Suggestions importantes pour la pr paration 1 Arrondir les angles de tous les rebords du stratifi d coratif pour viter qu ils ne s caillent 2 Arrondir les coins de la d...

Page 27: ...doit tre pos sur la conduite de gaz de cet appareil Quand un raccord flexible de gas est utilis il ne doit pas exc der une longueur de trois 3 pieds 36 pouces 91 4 cm Sauf indication contraire toutes...

Page 28: ...ermer ou ouvrir l alimentation en gaz de l appareil Effectuer toutes connexions de conduite suppl mentaires en amont du robinet d arr t de l alimentation en gaz S assurer que tous les raccords sont bi...

Page 29: ...oir fermer ou ouvrir l alimentation en gaz de l appareil Effectuer toutes connexions de conduite suppl mentaires en amont du robinet d arr t de l alimentation en gaz S assurer que tous les raccords so...

Page 30: ...utour des joints et des raccords il y a une fuite En cas de fuite fermer le robinet d alimentation de gaz serrer les raccords puis ouvrir le robinet de gaz et rev rifier s il y a des fuites Ne jamais...

Page 31: ...Si la prise doit tre mont e dans une armoire adjacente gauche ou droite un trou comme celui d crit ci dessus doit tre pratiqu dans la cloison entre les armoires La figure 4 page 5 illustre une cloison...

Page 32: ...desserrer le raccord en le tournant dans le sens anti horaire Retirer doucement le tourne crou du col du br leur Le raccord orifice doit se trouver pris dans le tourne crou R p ter les tapes 2 et 3 po...

Page 33: ...la fente de la vis de r glage 5 Serrer la vis de r glage fond dans le sens horaire 5 7 po lb 0 6 0 8 N m max Ne pas trop serrer 6 Remettre le passe fil en caoutchouc en place ainsi que le bouton de r...

Page 34: ...la figure 11 Une fois l appareil en place le d tendeur doit se trouver l emplacement indiqu la figure 3 4 ou 5 pages 4 5 et 6 Identifier le type de d tendeur de l appareil et suivre les instructions d...

Page 35: ...ou qu elle semble avoir un apport d air insuffisant faire appel un technicien de service apr s vente qualifi Il est normal que la flamme pr sente une pointe l g rement jaune avec le GPL Les d bits d a...

Page 36: ...d poser l appareil aux fins de d pannage 1 Fermer l alimentation en gaz au niveau de l appareil 2 D brancher l appareil de l alimentation lectrique s il y a lieu 3 D solidariser la conduite d alimenta...