background image

20 1/2"

Locate electrical 
supply junction 
box or 60" of 
electrical cable 
within shaded 
area.

Wall View

 (not to scale)

2 1/4"

10"

5 1/2"

5 1/2"

19"

Height:

Width:

Door swing:

Depth:

(not to scale)

Minimum horizontal clearance 
between the edge of the 
appliance and combustible 
construction extending from 
the cooking surface to 18" 
above the cooking surface is 
3" to the sides and 0" to the 
back (see solid areas).  6" 
Minimum is recommended.

30"

18"

Wall View

(not to scale)

Range

Upper cabinets 
can only be 13" 
deep maximum.
Over range 
cabinet is NOT 
recommended.

3"

36"

Countertop

height

30" Min. 

30" Minimum cutout width

29 7/8"

35 3/4"

35 3/4"

36 7/16"

29 7/8"

26 3/16"

35 3/4"

20 1/2"

Height at 0" leg adjustment:

Height at full leg adjustment:

26 3/16"

• Units depth including door handle is 28 3/8".
• Can be installed with the back against (0") a vertical
combustible wall  if equipped with optional backguard
kit, and the sides below the cooktop surface against
(0") combustible base cabinets.
• Electrical requirements: 120/240 or
120/208VAC,60Hz. 40 or 50 amp grounded circuit
protection is required.
• Proper operation requires use of range hood.
• Cabinetry over cooktop : 30" minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.  24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above
the surface units should be avoided.  If cabinet storage
is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• For Free-standing installations a slide-in range with
side panels measures 30 3/4" wide.   The height of the
countertop is 36" and countertop depth is 25".
• Island or peninsula installations with 24" deep base
cabinets must use flush back (no rear toe space)
cabinets to avoid range interference,.  If rear toe space
is desired, use 27" or deeper cabinets.

              See page 2 for additional information

www.dexpress.com  

DIMENSION EXPRESS  

Fax on Demand (775) 833-3600

•                             Dimensions (Actual Size)                            •

• NEVER reuse Data Sheets.  Data Sheets are subject to change without                          • Call Dimension Express if you have any questions at (775) 833-3633 •
notice.  Dimension Express is a FREE service bureau and is updated daily,                     • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data                    • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.

Slide In Gas Ranges:

JGS8750ADS, JGS8750ADB and JGS8750ADW

•                           Product Model Number (s):                            •

Subject to change without notice.  This system is designed to
be updated daily if necessary.  Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets.  Because of the difficulty or impracticability of deter-
mining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright ©  Dimension Express, 2002.

This Data Sheet Includes Information On

BN220.55 • A174B149 •  • 032603 • 95659 • 85619