background image

• Some European style cabinets are equipped with vinyl drawer and
door fronts.  The vinyl may not be designed to withstand the heat
produced by the normal operation of the self cleaning range.
Discoloration or delamination may occur.  To avoid possible damage,
Maytag recommends increasing the 30" cabinet opening to 31 1/4"
minimum and using a heat shield kit #CABKIT V.  The countertop
cutout must remain 30".
• Gas requirements:  Gas supply line should be 3/4".  Install a manual
shutoff valve in an accessible location in the gas line external to this
appliance for the purpose of turning on or shutting off gas to the
appliance.  The appliance is shipped from the factory equipped for use
with natural gas and can be converted to LP.  The maximum gas
supply pressure for both LP and natural gas is 14" WC.  Minimum
Pressure for Natural gas is 6" WC.  Minimum Pressure for LP gas is 11"
WC.

Kits:
• UXA9007ABB/Q/W: side panels.
• JXA9112AAP:  Backsplash.
• JXA9130AAP:  Backsplash.

30" countertop 

opening

Cutout opening

Slide-in installation

(not to scale)

23 1/4" 

Recommended.

From countertop 

front to rear cutout

36"

countertop height

30"

Cabinet opening

25" Normal 

countertop depth

24" 

Cabinet depth

You may need to 
shave or cut the trim of 
formed or metal front 
edged countertops to 
clear the 30 3/4" width 
of cooktop.

When replacing an existing unit, a 
maximum depth of 23 1/2" is acceptable.

23 5/8" 

minimum 

flat area

Additional Information:

Subject to change without notice.  This system is designed to be updated daily if necessary.  Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets.  Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright ©  Dimension Express, 2002.

www.dexpress.com

DIMENSION EXPRESS

Fax on Demand (775) 833-3600

• NEVER reuse Data Sheets.  Data Sheets are subject to change without                          • Call Dimension Express if you have any questions at (775) 833-3633 •
notice.  Dimension Express is a FREE service bureau and is updated daily,                     • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data                    • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.

Slide In Gas Ranges:

JGS8750ADS, JGS8750ADB and JGS8750ADW

•                           Product Model Number (s):                            •

This Data Sheet Includes Information On

BN220.55 • A174B149 •  • 032603 • 95659 • 85619

149