Specifications
Cabinet dimensions:
Height: 34 to 35 ¼ inches, adjustable
Width: 14 ¾ inches
Depth: 21 inches (cabinet only)
23 ½ inches (cabinet and door)
Weight: 95 lbs.
Shipping weight:
100 lbs. (approximate for standard models)
Average ice making capacity per 24 hours:
At 50°F water temperature:
70°F ambient: 35 lb/day
80°F ambient: 30 lb/day
90°F ambient: 23 lb/day
At 70°F water temperature:
70°F ambient: 32 lb/day
80°F ambient: 27 lb/day
90°F ambient: 20 lb/day
Electrical requirements:
115 VAC/60 Hz.
Power cord length:
7 feet
Compressor:
Piston type
Refrigerant charge:
5.0 oz. of R-134A
Equalized pressure:
72 psi at 77°F
System refrigerant control:
Capillary tube
Temperature control:
Electronic control with thermistor input
Condenser fan motor:
2.3 W, 1300 RPM
Water and drain controls:
Solenoid activated. Flow controlled
Installation
Location:
Unit can be installed freestanding or enclosed.
The front of the unit must be unobstructed for proper air
circulation and operation at all times.
Area should be ventilated with temperature above
55°F and below 90°F for proper operation.
Unit must be installed indoors away from the
elements of nature.
Unit must be on a level surface
capable of
supporting the loaded weight of the unit.
Refer to Appendix A, owners guide, for additional
information.
Electrical Requirements:
115 VAC, 60 Hz., single-phase power is
needed.
Use outlet with a 15 amp. delayed action fuse
or circuit breaker.
Do not put a fuse on the neutral or
ground of the circuit.
Properly grounded outlet is required for this
unit.
It is recommended that a single circuit
receptacle be used for this unit only. Do not use an
extension cord.
Water Requirements:
Use supplied water line fitting for water
connection to the rear of the unit.
Use cold, potable water supply only with
pressure between 20 to120 psi.
Use ¼ inch OD copper tubing. Plastic tubing
can be used, but may leak with age.
Use ¼ inch saddle shut-off valve. Check to
make sure valve complies with local codes. Do not use
self-piercing saddle valve or less than ¼ inch saddle
valve as water flow will be restricted.
A quality system water filter or local water filter
is recommended. A quality filter can remove particles
as well as remove unpleasant taste and odors from
water.
Softened water is not recommended.
Depending on mineral concentrations, this can produce
mushy white cubes that may stick together.
The above materials can be found at most local
plumbing supply stores or hardware stores. Follow the
manufactures installation instructions for water valves
and water line hook-ups. Make certain the waterline
and the valve do not leak prior to enclosing cabinet.
Installation