Troubleshooting
To avoid risk electrical shock, personal injury, or death,
always disconnect electrical power source to the freezer
before attempting to service, unless test procedures require
power to be connected. When removing any wiring from terminals they must be replaced on the same terminals.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
©2003 Maytag Appliances Company
16022323 Rev. 0
13
PROBLEM
CHECK
POSSIBLE CAUSE
REMEDY
Position of door light
activation over-ride
switch. Is it in the “on”
position?
If over-ride switch is in the
“on” position instead of
the “door” position, the
light will remain on with
the door closed. This is
intended for glass door
viewing with door closed.
Place over-ride switch in
the “door” position. Verify
light goes out when door
is closed by depressing
light activation switch and
confirming light goes out.
Over-ride
switch
operation.
Failed over-ride switch.
Replace over-ride switch