IMPORTANT (Please read carefully)
FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY
GROUNDED.
Do not use an extension cord or adapter
plug with this appliance. Follow National
Electrical codes and ordinances.
This warming drawer must be supplied
with 120V, 60Hz, and connected to an
individual, properly grounded branch cir-
cuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
IMPORTANT (Please read carefully)
The power cord of this ap-
pliance is equipped with
a 3-prong (grounding)
plug that mates with
standard 3-prong
grounding wall recep-
tacle to minimize the possibility of electric
shock. The customer should have the wall
receptacle and circuit checked by a quali-
fied electrician to make sure the receptacle
is properly grounded and has the correct
polarity.
•
Where a standard 2-prong wall re-
ceptacle is encountered, it is the
personal responsibility and obliga-
tion of the customer to have it re-
placed with a properly grounded 3-
prong wall receptacle.
Do not, under any circumstances, cut or re-
move the third (ground) prong from the power
cord.
DO NOT USE AN EXTENSION CORD.
• A properly grounded 3-prong receptacle
should be located within reach of the
drawer’s 56” long power cord.
• Locate the receptacle in an adjacent cabi-
net.
– Within 42” of the right side or,
– Within 16” of the left side or,
– A recessed receptacle may be located
on the right side of the cutout,
7” maximum from the back of the
cabinet. In this location, the excess
power cord should be coiled to the
right side of the unit using the cord clip
provided.