background image

8

2.

Position the 4 vertical supports (A) with notches at the bottom 
and attach to the range hood using 16 - 4.2 x 8 mm screws. 

3.

Attach the horizontal support (B) using 8 - 4.2 x 8 mm screws.

4.

Attach a second set of vertical supports (A) and set the 
vertical height (B). See “Installation Dimensions” in the 
“Location Requirements” section to help determine the 
desired dimension for the vertical height (B). Secure with 
16 - 4.2 x 8 mm T20

®

 screws.

5.

Using 2 or more people, lift the range hood assembly and 
attach it by snapping the vertical supports to the spring clips 
in the upper horizontal support bracket that is mounted to the 
ceiling.

NOTE:

 The range hood assembly must be held in place while 

installing the screws in the next step.

6.

Install 16 - 4.2 x 8 mm screws and tighten to secure.

Connect Vent System

1.

Install vent system.

2.

Push duct over the exhaust outlet. Seal all connections with 
vent clamps.

3.

Use caulk to seal all openings.

Non-Vented (Recirculating) Installation

1.

Attach the air deflector to the upper horizontal support using 
4 mounting screws.

2.

Measure the length of 6" (15.2 cm) duct needed to connect 
the transition to the deflector.

NOTE:

 Vent should fit up inside the deflector 1" (2.5 cm) 

minimum.

3.

Install vent between the transition and the deflector.

NOTE:

 To make vent installation easier, temporarily remove 

the deflector from the chimney support bracket and replace 
after vent section is in place.

4.

Seal all connections with vent clamps.

Make Electrical Connection

1.

Disconnect power.

2.

Remove terminal box cover.

3.

Remove the knockout in the terminal box, and then install a 
UL listed or CSA approved

 ¹⁄₂

" (12.7 mm) strain relief.

A. Vertical supports
B. Horizontal support

A. Vertical supports
B. Vertical height

A. Mounting screws

B

A

A

B

A

A

A

A. Deflector
B. Mounting screws

A. Knockout
B. Terminal box

C. Terminal box cover

B

B

A

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

C

B

Summary of Contents for JXI8536DS0

Page 1: ...nnair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou...

Page 2: ...OTTE 28 Nettoyage 28 SCH MA DE C BLAGE 29 ASSISTANCE OU SERVICE 30 Au Canada 30 Accessoires 30 GARANTIE 31 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 4: ...ial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and...

Page 5: ...to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air...

Page 6: ...k Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring fo...

Page 7: ...power supply cable and drill a 1 3 cm diameter hole for wire access 2 Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordin...

Page 8: ...ulk to seal all openings Non Vented Recirculating Installation 1 Attach the air deflector to the upper horizontal support using 4 mounting screws 2 Measure the length of 6 15 2 cm duct needed to conne...

Page 9: ...port frame The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover 2 Secure the upper duct covers together with two 3...

Page 10: ...ced over the plastic clip to secure the lower duct covers together at the bottom 7 Secure the lower duct covers together at the top using plastic clips 2 Use one plastic clip on each side 8 Secure the...

Page 11: ...tween the gas cooktop and electric cooktop modes The Auto button light will flash 5 times when the range hood is changed to the electric cooktop mode Auto Sense is now set to work with electric cookto...

Page 12: ...ing Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge and then rinse with clean water and wipe dry Metal Grease Filter 1 Open the stainless...

Page 13: ...fications Power Supply Frequency Power Absorbtion 120 VAC 60 HZ 420 W Motor Resistance Blue Black Blue Grey Blue Red Blue White 9 8 14 3 18 21 6 SE130B RD M 3 2 1 4 5 6 7 8 9 BU YL GN BR YL WH RD GY B...

Page 14: ...h any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Can...

Page 15: ...rs preservation solutions etc 5 Defects or damage caused by the use of non genuine Jenn Air parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abus...

Page 16: ...W10674115D 2015 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 3 15 Printed in Mexico Imprim au Mexique...

Reviews: