9
3. Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.
4. The ice maker is equipped with a built-in water strainer. If
your water conditions require a second water strainer, install
it in the
¹⁄₄
" (6.35 mm) water line at either tube connection.
Obtain a water strainer from your nearest appliance dealer.
5. Plug in refrigerator or reconnect power.
Move the Refrigerator Drawers to
Final Location
1. Place top of cardboard carton or plywood under the
appliance. Remove dolly.
2. Do not remove film or cover.
3. Plug into a grounded 3 prong outlet.
4. Move the refrigerator drawers straight back and evenly in
front of the opening.
Level the Refrigerator Drawers
IMPORTANT:
■
Style 2–Overlay: Be sure to install the custom overlay drawer
panels before leveling the refrigerator drawers for the Overlay
Model. See “Style 2: Install Custom Overlay Drawer Panels.”
■
Before installing the refrigerator drawers, be sure that the
countertop is level.
■
If the countertop is not level, adjust the refrigerator drawers’
leveling legs until the appliance is square with the countertop.
Be sure to maintain
³⁄₈
" (9.5 mm) minimum gap between the
top of the drawer and the countertop.
1. Open the top drawer and place the level across the top
drawer as shown. Check the level from left to right.
2. Turn the leveling legs (front and back) until the top drawer
measures level from left to right.
3. Remove the level and close the top drawer. Check the gap
between the top of the drawer and the countertop. If the gap
measures less than
³⁄₈
" (9.5 mm) minimum, turn all four
leveling bolts equally to the left to raise the leveling legs (this
will lower the appliance). Recheck the level.
4. Open both drawers less than midway. Place the level on the
side flange beside the drawers as shown. Turn the front
leveling bolts together in order to either raise or lower the
appliance until the sides of the refrigerator drawers are
plumb.
A. Plug
B. Compression nut
C. Pex tubing
A
B
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A. Check the level from left to right.
A. Check the level
from front to back.
A
A