CAPACITANCE MEASUREMENTS
WARNING:
To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any capacitance
measurements. Remove the batteries and unplug the line cords.
1. Set the rotary function switch to the green
Ω
CAP
position.
2. Insert the black test lead banana plug into the negative
COM
jack.
Insert the red test lead banana plug into the positive
V
jack.
3. Press the
MODE
button to indicate “
nF
” on the
display.
4. Touch the test leads to the capacitor to be tested.
5. The test may take up to 3 minutes or more for large
capacitors to charge. Wait until the readings settle
before ending the test.
6. Read the capacitance value in the display
FREQUENCY/DUTY CYCLE MEASUREMENTS (ELECTRONIC)
1. Set the rotary function switch to the green “
Hz %
”
position.
2. Press the Hz/% button to indicate “
Hz
” in the display.
3. Insert the black lead banana plug into the negative
COM
jack and the red test lead banana plug into the
positive
Hz
jack.
4. Touch the test probe tips to the circuit under test.
5. Read the frequency on the display.
6. Press the
Hz/%
button again to indicate “
%
” on the
display.
7. Read the % of duty cycle on the display.
JTM-105a V3.0 10/07
13