background image

PRIMA_pH_1BC6051

NORMAL

ATC

REL

WASH

    7.00 

pH

C

25.0

1

2

O

Online pH/ORP Analyzer

Operation  Manual

innoCon 6800P

WALL MOUNTING

JENSPRIMA INSTRUMENTS

Summary of Contents for innoCon 6800P

Page 1: ...PRIMA_pH_1BC6051 NORMAL ATC REL WASH 7 00 pH C 25 0 1 2 O Online pH ORP Analyzer Operation Manual innoCon 6800P WALL MOUNTING JENSPRIMA INSTRUMENTS...

Page 2: ......

Page 3: ...ction Installation Display Electrical Connection Configuration Mode Calibration Mode Maintenance General Setting Controller Installation Sensor Installation Analysis System 14 14 15 pH Calibration ORP...

Page 4: ...se use sensors manufactured by JENSPRIMA Damages to the instruments caused by the use of sensors not manufactured by JENSPRIMA withinthe warrantyperiod will not be covered by the warranty Only technic...

Page 5: ...ronmental monitoring industrial processes swimming pools and so on 1 innoCon 6800P Controller 2 Fixed bracket 3 Operation Manual 4 innoSens pH ORP Sensor Need to purchase separately Features The lates...

Page 6: ...oSens 125 pH Sensor Applicable to pH measurement of high temperature and high pollution wa stewater innoSens 130 pH Sensor Applicable to pH measurement of high temperature sterilization high temperatu...

Page 7: ...e case from the front of the panel of the case insert screws from the back cover andthen lock the fastening block to the fastening bar from the back of the panel Panel Mounting Dimension Wall pipe mou...

Page 8: ...water from damaging the electrodes Sheath components and installation innoCon 6800 Monitor Manual Page 6 innoSens 120 pH Electrode pH 0 14 5 70 Controller innoCon 6800P Sensor innoSens pH ORP Sensor F...

Page 9: ...cted when the two wire connection is made Power End Center axis of the electrode Cable of sensor Shielded wire Empty feet Connect with the temperature probe Power End RS485 output Modbus RTU Protocol...

Page 10: ...key Arrows key Return to previous menu Accept the gure input or menu chosen or o the backlight of the display Entry into the setup mode is protected by password The default password is 0022 to the pre...

Page 11: ...ent 1 4 00mA Current 2 4 00mA 1 AnalysisSystem Temperature System Measurement System Damping 1 Output Analog current 1 Analog current 2 Relay1 Relay2 Relay3 1 General Language Serial Number Restore 1...

Page 12: ...revious menu 2 Select Restore and press Enter 3 Press upward and downward arrows to select YES or NO and press Enter General 2 Select Language press Enter and you will get a list of available language...

Page 13: ...ional range 5 0 5 0 30 0 41 0 Optional range 10 120 14 248 3 Select your desired unit of temperature or and temperature o set 5 5 previous menu Damping 2 previous menu Measurement System Notes The lar...

Page 14: ...ent2 4 00mA 20 00mA 100 0 0 00mA 000 0 Optional ranges 10 0 110 0 14 0 230 0 Optional ranges 0 0 120 0 32 0 248 Optional ranges 1 00 1 00mA mA Offset 1 Relay 1 2 Select Relay1 and press Enter previous...

Page 15: ...ng relay Interface ID address Range 1 255 1 001 Diagnosis 2 Press Con g to return toprevious menu Diagnosis Relay 1 Relay 2 Press Enter to test whether Relay3 is closed or open Press Enter to output 4...

Page 16: ...the first point of the standard solution enter the current standard solution temperature at MTC only select the first point the standard solution press Enter to start cabration automatically when stab...

Page 17: ...and Press ENTER 6 97pH 25 0 7 00pH 1 1 Clean and dry the electrode and put it into the first point of the standard solution enter the current standard solution temperature at MTC only select the firs...

Page 18: ...ry dirty Regular cleaning Keep the exudation interface of the reference electrode clean Keep the glass film clean Cleaning Cycle Cleaning requirements are different based on different applications Rec...

Page 19: ...t displays 02 it means the address is incorrect 0x01 0x03 0x02 0x02 0xBC 0xB895 1 byte 1 byte 1 byte N byte 2 byte CRC16 1 Data addresses 0 0 release 1 closed Relay1 status 1 0 1 2 0 release 1 closed...

Page 20: ...Jensprima Instruments Shanghai Co Ltd Web Email info jensprima com 2013 JENSPRIMA INSTRUMENTS all rights reserved www jensprima com...