EXTENSION CABLE SELECTION 

 

The machines are factory fitted with a 2 metre length of cable having three 
conductors 1.5mm² LIVE, NEUTRAL and EARTH. 

If it becomes necessary to fit an extension cable from the power source,     
care  must  be  taken  in  using  a  cable  of  adequate  capacity.  Failure to do so 
will result in a loss of traction by the magnet and a reduction of power      
from the motor. 

 

Assuming a normal AC supply of the correct voltage, it is recommended 
that the following extension lengths shall not be exceeded: 

 

 

For 110v supply: 

3.5metres of 3 core  x 1.5mm² 

For 230v supply: 

26metres of 3 core x 1.5mm² or 
17metres of 3 core x 1.0mm² 

ALWAYS DISCONNECT THE MACHINE FROM THE POWER SOURCE WHEN 
CHANGING CUTTERS. 

 

[5]

 

MOUNTING OF CUTTERS 

The machine has normal Weldon shank, 3/4“. 
The following procedure is to be used when mounting cutters. 

 

-

 

Take  appropriate  pilot  and  place  through  hole  in  shank  of  cutter. 

 

-

 

The machine is delivered with a qick release system. To open the shank turn 

the release anti clockwise. 

 

-

 

Put the Weldon arbor into the shank and close the release. 

Summary of Contents for 490140S

Page 1: ...Magnetic Drilling Machine MAGPRO 40 1S Adjust Swivel OPERATOR S MANUAL...

Page 2: ...or other normative document s EN ISO12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN60204 1 A1 2009 Safety of machinery Electrical equipment of machin...

Page 3: ...SELECTION 5 MOUNTING OF CUTTERS 6 REMEDIES FOR HOLE MAKING PROBLEMS 7 CIRCUIT Page 3 4 6 7 7 8 11 8 PART LIST 12 List of Contents with Magnetic Drill Unit Check List 1 Operator s Manual YES NO 2 Coola...

Page 4: ...2 MAGPRO 40 1S Adjust Swivel Ref 490140S...

Page 5: ...material should be positioned under the magnet and work piece to equate to a suitable material thickness If this is not possible an alternative secure method of restraining the machine MUST be used 4...

Page 6: ...NG TO OPERATE Always wear approved eye and ear protection when the equipment is in operation Failure to do so may result in personal injury Disconnect from the power source when changing cutters or wo...

Page 7: ...OR ON AND OFF If the machine is accidentally dropped always thoroughly examine the machine for signs of damage and check that it functions correctly before trying to drill a hole Regularly inspect the...

Page 8: ...duced into the work surface Excessive pressure is undesirable it does not increase the speed of penetration Always ensure that the slug has been ejected from the previous hole before commencing to cut...

Page 9: ...voltage it is recommended that the following extension lengths shall not be exceeded For 110v supply 3 5metres of 3 core x 1 5mm For 230v supply 26metres of 3 core x 1 5mm or 17metres of 3 core x 1 0...

Page 10: ...et Use extreme care file only imperfections flush to surface Confirm power supply and output from control unit 2 Cutter skips out of centre punch mark at initiation of cut Magnetic base is not holding...

Page 11: ...djust grub screws Swarf accumulated packed inside cutter Clear cutter Incorrect speed selection Select appropriate speed 4 Excessive cutter breakage Steel swarf or dirt under cutter Remove cutter clea...

Page 12: ...heck pilot groove and arbor internally for dirt or apply oil externally Even a small amount of oil is very effective Select appropriate speed 5 Excessive cutter wear Incorrectly re sharpened cutter In...

Reviews: