- 7 -
[4]
EXTENSION CABLE SELECTION
The machines are factory fitted with a 2 metre length of cable having three
conductors 1.5mm² LIVE, NEUTRAL and EARTH.
If it becomes necessary to fit an extension cable from the power source,
care must be taken in using a cable of adequate capacity. Failure to do so
will result in a loss of traction by the magnet and a reduction of power
from the motor.
Assuming a normal AC supply of the correct voltage, it is recommended
that the following extension lengths shall not be exceeded:
For 110v supply:
3.5metres of 3 core x 1.5mm²
For 230v supply:
26metres of 3 core x 1.5mm² or
17metres of 3 core x 1.0mm²
ALWAYS DISCONNECT THE MACHINE FROM THE POWER SOURCE WHEN
CHANGING CUTTERS.
[5]
MOUNTING OF CUTTERS
The machine has normal Weldon shank, 3/4“.
The following procedure is to be used when mounting cutters.
-
Take appropriate pilot and place through hole in shank of cutter.
-
The machine is delivered with a qick release system. To open the shank turn
the release anti clockwise.
-
Put the Weldon arbor into the shank and close the release.