background image

2

 

General Description

 

Given the bottle is full of liquid during normal spraying, if the spray volume is 

reduced, the filter may be blocked and it needs to be replaced; if the atomization 

effect of spray is getting poor or the nozzle does not perform the spraying, the 

nozzle may be blocked and it needs to be cleaned. 

 

Instructions of Filter Replacement

 

Steps 

1. Unscrew the bottle, rinse the outer surface of liquid suction hose and filter with 

clean water, therefore removing the liquid on suction hose and filter. Add 

400mL of clean water to the bottle, install the bottle, turn on the sprayer, and 

spray clean water to flush the liquid inside the liquid hose. 

 

2. Unscrew the bottle counterclockwise, and pull out the entire suction hose 

assembly by hand according to the following diagram. 

 

 

Note

 

a.

 

The installation direction is that the fine filter (Part 1) is on the top and the 

coarse filter (Part 2) is at the bottom (flat ends of coarse filter and fine filter are 

the liquid inlet, and the flat ends are all facing down). 

b.

 

If the replacement is required, the coarse filter and the fine filter must be 

replaced at the same time. 

c.

 

Only the filter recommended by the manufacturer can be used, otherwise it will 

cause poor liquid suction or frequent nozzle blockage, or even reduce the 

service life of liquid pump. 

d.

 

During the replacement process, always keep hands and parts of suction hose 

Summary of Contents for JES-HS60

Page 1: ...1 JES HS60 Handheld Electrostatic Sprayer Filter Replacement Nozzle Cleaning USER GUIDE ...

Page 2: ...er and spray clean water to flush the liquid inside the liquid hose 2 Unscrew the bottle counterclockwise and pull out the entire suction hose assembly by hand according to the following diagram Note a The installation direction is that the fine filter Part 1 is on the top and the coarse filter Part 2 is at the bottom flat ends of coarse filter and fine filter are the liquid inlet and the flat end...

Page 3: ...3 clean to prevent impurities from affecting the liquid pump performance 3 Screw on the bottle again and the filter replacement is completed ...

Page 4: ...the hose then take off the bottle remove the nozzle cap by rotating counterclockwise with the nozzle cap removal tool in accordance with the assembly diagram and then take out the nozzle 2 In accorda nce with the assembly diagram unscrew the nozzle core counterclockwise with a flat blade screwdriver ...

Page 5: ... needle especially those foreign matters in two grooves on the inner side of nozzle After scraping rinse the components in the nozzle assembly diagram with clean water 4 According to the assembly diagram screw on the nozzle core clockwise with a flat blade screwdriver ...

Page 6: ...s coaxial with the nozzle It is recommended to install the nozzle in the vertical direction of the spray gun as shown below which makes it easier to achieve that the black rubber pad is coaxial with the nozzle 6 Screw on the bottle and the nozzle cleaning is completed Note Always keep hands components and all appliances clean in abovementioned steps to prevent impurities from affecting the liquid ...