PRODUCT DESCRIPTION

 

 

The Jerguson model SAS-16 is a snap action magnetic level switch and has been designed to operate as 
a point level switch for magnetic liquid level gauges.  Please read this manual in its entirety before 
installing the switch.  Switch housing, nipple, and enclosure (when applicable) are constructed of 6061 T6 
aluminum, designated by # = null, or 316SS designated by # = T. 
 
All installation steps should be performed by a qualified technician and should be performed in accordance 
with all applicable national and local codes. 
 
 

OPERATION 

 

The normal state of the SAS-16 is when the magnetic float is below the centerline/activation level of the 
switch.  In this normal state, the "A" leads are N/O and the "B" leads are N/C.  When the float rises above 
the activation level, the switch changes states, and persists until the float passes the activation level once 
more. 

INSTALLATION 

To field mount the SAS-16 switch, simply tighten the provided hose clamps around both ears of the switch 
assembly & the Magnicator chamber.  Be sure to install the switch in the upright position, with "T" or "TOP" 
facing up (denoted on the ear).  Also, hose clamps will have to be fed behind any indicator or accessories, 
taking care not to unnecessarily alter their positions. 
 
Additional switch installation considerations:  

1)  Switch location should not be beyond either the travel range of the float, or the outer-most  

process connections. 

2)  Switch orientation (left, right, or back side, etc.) should be within the active magnetic field. 

Note label restrictions of active magnetic field on flash-proof designs. 

3)  Consult factory regarding Specific Gravity (SG) prior to mounting multiple switches at the 

same locations. 

 

When supplied with flying leads, an approved sealing fitting must be within 12mm (.47

”) of enclosure. All 

sealing fittings must be certified with appropriate ratings for the area. 
 
For additional information refer to the appropriate control and installation drawing. 
 

CI-SAS-16: UL/CUL 

 

CI-SAS-16-EX: ATEX/IECEx 

 
 

SUPPLIED WITH FLYING LEADS: 
Part No. A25669-#, A25669-CE-#, A26617-# and A26617-CE-# 

 
The switch can be wired as a form C switch as shown below. 
 
 
 
 
 
 
 
 
 

 