42
TROUBLE PROBABLE
CAUSES
REMEDY
1. Circuit not complete.
Check switch, leads, fuse etc, replace or
reconnect properly.
Fails to start.
2. Power may be off.
Check cable connection.
3. Overload relay off.
Reset overload relay.
1. Voltage below what is rated.
Check power source voltage. Reset
input voltage of parameter according to
power supply. (VS-model)
2. Connecting cable too small.
Enlarge connecting cable.
Incorrect Spindle speed.
3. Improper or loose connection of lead.
4. Failure on spindle select knob.
Recheck all leads connecting.
Replace it.
5. Overload.
Reduce cutting speed and depth or feed
rate.
Wrong rotation.
Wrong sequence of phases.
Reverse any two leads connecting for
motor.
1. Motor loosely mounted.
Tighten mounting bolts.
2. Strained mounting frame.
Shim to motor feet for equal mounted.
Motor noisy and vibration.
3. Bent or sprung motor shaft.
Straighten or replace it.
4. Foundation inadequate or motor feet
uneven.
Stiffen mounting place or add shims
under foot pad.
1. Excess belt tension.
Adjust belt tension.
2. Cooling fan failure.
Check the fan in proper work.
Overheat in motor.
3. Badly worn on bearing.
4. Short grease in bearing.
Replace bearing.
Replenish grease.
5. Overload.
Reduce cutting speed or feed rate.
6. Incorrect speed range running
continuous.
Change speed range and adjust speed
select knob.
1. Wrong rotation.
Reverse any two leads to pump.
Coolant pump failure.
2.Coolant not enough or return filter
obstructed.
Replenish coolant or clean return filter in
chip tray.
3.Overload relay off.
Reset overload relay
Inverter alarm. (VS-model)
1. Operation
error.
2. Wrong set of parameter.
3.Circuit not complete
4.Footbrake switch keep in touch.
5.Inverter problems
Switch off for 20 seconds and switch on
again as reset.
Referring to instruction manual of
Inverter or contact with manufacturer.
Check the power source and reconnect
properly.
Re-positioning the switch and tighten it.
Return the inverter to manufacturer for
repair or replace.