EN - 12
BA-0006 • 2020-02-08
6 Putting into operation
SynMag 2600/3100/3600/4100/5100
6 Putting into operation
When positioning the device, ensure there is sufficient room for the inlet and outlet of the cooling air so that
the specified duty cycle can be achieved. Do not expose the system to moisture, weld spatter or direct sparks
during welding operations. Do not use the system outdoors when raining.
Connecting the shielding gas cylinder
Place the shielding gas cylinder on the back of the shielding gas welding system and secure it with the chain.
Connect the cylinder pressure reducer and check that all connections are tight.
Connecting the welding torch cable assembly
Connect the welding torch with the central socket and water supply.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly
and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
CAUTION
Risk of injury
Heightened noise pollution
• Wear personal protective equipment: ear protection.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of injury
The feet may be crushed by the power source suddenly rolling.
• Check the stability of the machine.
• Only position the machine on even surfaces.
CAUTION
Risk of injury
High weight.
• Take care to slow down in time when moving the device.
NOTICE
• Please note the following instructions:
Product description can be found on Page EN-5
• Only qualified personnel are permitted to perform work on the device or system.
• Components must only be used in environments with sufficient ventilation.