background image

JET   

 

 

 

Safety warnings 

General air tool warnings 

1. 

Read  and  understand  this  entire  manual 
before attempting assembly or operation. 

2. 

Read and understand all warnings posted on 
the tool and in this manual. Failure to comply 
with all of these warnings may cause serious 
injury. 

3. 

Replace  warning  labels  if  they  become 
obscured or removed. 

4. 

Do not use this tool for other than its intended 
use. If used for other purposes, JET disclaims 
any  real  or  implied  warranty  and  holds  itself 
harmless from any injury that may result from 
that use. 

5. 

Always wear approved safety glasses or face 
shield  while  using  this  tool.  (Everyday 
eyeglasses only have impact resistant lenses; 
they are 

not 

safety glasses.) 

6. 

Wear  ear  protectors  (plugs  or  muffs)  if  the 
noise exceeds safe levels. 

7. 

Wear  gloves  and  protective  clothing  if 
operation produces sparks or flying particles. 
Gloves  should  be  tight-fitting,  without  frayed 
fingers  or  hanging  threads.  Keep  hands  and 
body away from the working area of tool. 

8. 

Do  not  operate  an  air  tool  continually  at  full 
throttle without a work load on the tool. 

9. 

The air tool must be properly lubricated before 
operating.  

10.  Never start a percussion type air tool (chipper, 

breaker,  buster,  etc.)  without  securing  the 
tooling  in  the  retainer  and  placing  the  tip 
against the work surface. 

11.  Do  not  operate  air  tool  without  its  guards  in 

place. Do not modify the tool. 

12.  Do  not  operate  this  tool  while  tired  or  under 

the  influence  of  drugs,  alcohol,  or  any 
medication. 

13.  Adopt  a  comfortable  posture  with  proper 

balance,  and  maintain  secure  footing  at  all 
times.  Non-slip  footwear  or  anti-skid  floor 
strips are recommended. 

14.  Do not wear loose clothing or jewelry. Confine 

long hair. 

15.  Excessive  air  pressure  and  too  much  free 

rotation may decrease life of the tool and may 
cause a hazardous situation. 

16.  Check  air  hoses  for  wear,  and  keep  them 

away  from  heat  and  sharp  edges.  Repair  or 
replace  damaged  air  hose  immediately.  Do 
not carry tool by the air hose. 

17.  Air  hose  may  cause  tripping  hazards;  keep 

hose away from traffic areas. 

18.  Do not  use this tool  near flammable  objects, 

or  in  potentially  explosive  environments.  Do 
not use near live electrical wires. 

19.  Do  not  use  power  tools  in  damp  or  wet 

location,  or  expose  them  to  rain.  Keep  work 
area well lighted. 

20.  Do  not  leave  a  connected  tool  unattended. 

When  not  in  use,  disconnect  tool  from  air 
source. 

21.  Shut off air supply and discharge any residual 

pressure  from  tool  before  removing  hose, 
making  adjustments,  changing  accessories, 
or storing tool. 

22.  Make sure tool is switched off, and your finger 

off the trigger, before connecting to air supply. 

23.  Remove adjusting keys and wrenches before 

turning on tool. 

24.  Keep  visitors  a  safe  distance  from  the  work 

area. 

Keep children away.

 

Summary of Contents for 505800

Page 1: ...Pneumatic Needle Scaler 505800 JAT 800 Operation Parts Manual M 505800 Edition 2 11 2018 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET ...

Page 2: ...on needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law Applies This wa...

Page 3: ...p against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol or any medication 13 Adopt a comfortable posture with proper balance and maintain secure footing at all times Non slip footwear or anti skid floor strips are recommended 14 Do not wear loose clothing or jewelry Conf...

Page 4: ...h clamps or vise do not hold workpiece by hand 36 Use both hands to operate needle scaler Keep hands away from needle area 37 Use only needles specifically designed for use with a needle scaler 38 Keep needles against work surface Do not use excessive force let the tool do the work 39 If needle scaler will not remove material from the work surface discontinue use Use alternate methods for removal ...

Page 5: ...n this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystanders should be first priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site...

Page 6: ...lever Grip Inline Overall Length 15 in 381 mm Housing material Steel Net weight 6 28 lb 2 85 kg Shipping weight 6 68 lb 3 03 kg 1 The specified values are emission levels and are not necessarily to be seen as safe operating levels As workplace conditions vary this information is intended to allow the user to make a better estimation of the hazards and risks involved only Specifications were curren...

Page 7: ...aler Clean only 6 to 8 inches of surface area at one time and make 2 or 3 passes 5 Hold needle scaler firmly with both hands at approximately 45 degree angle from work surface 6 Place needles upon work surface and press throttle lever Pressure against throttle lever determines speed of tool Do not exert excessive pressure against work surface let the tool do the work 7 Release throttle lever to st...

Page 8: ...r the job Continued use in either capacity will cause damage to the tool Tool Pressure JET Air Tools operate on 70 to 100 psi pounds per square inch air pressure measured at the tool when the tool is operating Set tool to 90 psi unless indicated otherwise Pressure in excess of 100 psi will shorten the life of the tool Air System Recommendations Equip the air compressor intake with a replaceable ai...

Page 9: ...JET 9 Figure 2 Recommended arrangement of air piping and air line system ...

Page 10: ...nt lubrication Lubricate with air tool oil according to instructions in this manual Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator setting set air pressure to 90 psi Check for loose connections Moisture or obstruction in air hose Air supply must be clean and dry Clean out air hose s and remove any kinks or bends Improper si...

Page 11: ...ollowing pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and accurately ...

Page 12: ...12 JAT 800 Pneumatic Needle Scaler 505800 JAT 800 Needle Scaler exploded view ...

Page 13: ...9597 Lock ring 1 28 730218 Alignment shim 2 29 729608 Rear valve block 1 30 1012591 Pin 2 31 729604 Valve 1 Index Part No Description Qty 32 729606 Front valve block 1 33 730219 Piston 1 35 731008 Barrel sleeve 1 36 731009 Nose 1 37 731010 Key 1 38 730220 Driver retainer 1 39 730221 Retainer buffer 1 40 JAT800 40 Barrel 1 41 730222 Retainer cap 1 45 730224 Needle driver 1 46 N307 Needle set 3x180L...

Page 14: ...14 JAT 800 Pneumatic Needle Scaler This page intentionally left blank ...

Page 15: ...JET 15 This page intentionally left blank ...

Page 16: ...16 JAT 800 Pneumatic Needle Scaler 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Reviews: