background image

 

Safety Rules for the AFS-2000 

 
1.  Read and understand instruction manual before installing or operating air cleaner. 
 
2.  To reduce the risk of injury disconnect the air cleaner from the power source (unplug) before servicing 

or changing filters. 

 
3.  If ceiling mounted, bottom of air cleaner must be at least 7 feet above the floor. 
 
4.  If ceiling mounted, mounts must be anchored to building structure which will support a minimum of at 

least 220 pounds.  Never mount to surfaces such as dry wall or false ceiling grids, etc. 

 
5.  To reduce the risk of electrical shock, do not expose air cleaner to water or rain. 
 
6.  Never duct a machine directly into the air cleaner. 
 
7.  To avoid a potentially dangerous situation, do not use this equipment to filter volatile fumes or smoke.  

This air cleaner is designed and intended for the filtration of air borne wood dust only.  It is neither 
designed nor intended for any other purpose whatsoever. 

 
8.  Failure to comply may result in serious injury and / or property damage. 
 

Introduction 

This manual is provided by Walter Meier (Manufacturing) Inc., covering the safe operation and 
maintenance procedures for a JET Model AFS-2000 Air Filtration Unit. This manual contains instructions 
on installation, safety precautions, general operating procedures, maintenance instructions and parts 
breakdown. This machine has been designed and constructed to provide years of trouble free operation if 
used in accordance with instructions set forth in this manual. If there are any questions or comments, 
please contact either your local supplier or Walter Meier. Walter Meier can also be reached at our web 
site: www.waltermeier.com. 

Specifications 

Model Number .......................................................................................................................AFS-2000 
Stock Number .......................................................................................................................... 708615 
Outer Filter ............................................................................................................................ 5  Microns 
Inner Filter............................................................................................................................... 1  Micron 
Overall Dimensions (LxWxH/in) .......................................................................................... 44 x 24 x 20 
Sound Rating @ 3ft ................................................................................................ High Speed 73.8 dB 
......................................................................................................................... Medium Speed 62.0 dB 
.............................................................................................................................. Low Speed 59.1 dB 
Air Flow.............................................................................................................. High Speed 1700 CFM 
..................................................................................................................... Medium  Speed 1200 CFM 
............................................................................................................................ Low Speed 800 CFM 
Filter Cycle ................................................................................................................... 1.88 per minute 
Cycles (20’x20’x8’).......................................................................................................... 31.91 per hour 

Motor ............................................................................................................. 1/3 HP, 115V, 

115V Only

 

Shipping Size (LxWxH/in) ................................................................................................... 46 x 26 x 22 
Net Weight ............................................................................................................................... 110 lbs. 
Shipping Weight ....................................................................................................................... 121 lbs. 
 
The above specifications were current at the time this manual was published, but because of our policy of 
continuous improvement, Walter Meier reserves the right to change specifications at any time and without 
prior notice, without incurring obligations. 

Summary of Contents for AFS-2000

Page 1: ...arts Manual AFS 2000 Air Filtration WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Part No M 708615 Ph 800 274 6848 Revision B 03 2010 www waltermeier com Copyright 2010 Walter Meier Manufacturing Inc ...

Page 2: ...age prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must accompany the merchandise If our inspection discloses a defect we will repair or replace the product or refund the purchase price at our option We will return the repaired product or replacement at ou...

Page 3: ...es invite accidents 6 DON T USE IN DANGEROUS ENVIRONMENT Don t use power tools in damp or wet locations or expose them to rain Keep work area well lighted 7 KEEP CHILDREN AND VISITORS AWAY All children and visitors should be kept a safe distance from work area 8 MAKE WORKSHOP CHILDPROOF Use padlocks master switches or remove starter keys 9 DON T FORCE TOOL It will do the job better and be safer at...

Page 4: ... 21 NEVER LEAVE TOOL RUNNING UNATTENDED TURN POWER OFF Don t leave tool until it comes to a complete stop 22 DRUGS ALCOHOL MEDICATION Do not operate tool while under the influence of drugs alcohol or any medication 23 MAKE SURE TOOL IS DICONNECTED FROM POWER SUPPLY while motor is being mounted connected or reconnected 24 WARNING Some dust created by power sanding sawing grinding drilling and other...

Page 5: ... the safe operation and maintenance procedures for a JET Model AFS 2000 Air Filtration Unit This manual contains instructions on installation safety precautions general operating procedures maintenance instructions and parts breakdown This machine has been designed and constructed to provide years of trouble free operation if used in accordance with instructions set forth in this manual If there a...

Page 6: ... connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Use only three wire extension cords that have three prong grounding plugs and three pole receptacles that accept the tool s plug Repair or replace a damaged or wor...

Page 7: ...ic dust which is generated throughout the work area Assembly Mounts must be anchored to building structure which will support a minimum of 220 pounds Never mount to surfaces such as dry wall or false ceiling grids etc 1 Remove all packing from inside of the unit by opening the side panel 2 Make sure the hex nut A Figure 2 is threaded all the way up the eyebolt B Figure 2 3 Place a flat washer C Fi...

Page 8: ...anual button C Figure 3 on the backside of this unit which controls the speed On Off button D Figure 3 turns the unit on and off There is also a manual on off button E Figure 3 on the backside of the unit Pressing this button will turn the machine on Low Overload reset switch F Figure 3 will pop in the case of overload Wait 3 5 minutes and press the reset switch Changing the Filters To reduce the ...

Page 9: ...ace the cover and four bolts Diffuser The diffuser A Figure 7 should not need any maintenance You can remove from the side of the cabinet The filters should be replaced depending on the amount of usage and the environment of your shop Clogged filters will reduce the amount of air circulation Order replacement filters using the below listed stock numbers 330025 Air Diffuser 708722 Outer Filter card...

Page 10: ...10 Parts Breakdown ...

Page 11: ...tal frame washable 24 x20 x2 18 330025 Air Diffuser 24 x20 x1 1 19 330026 Motor 1 CA003000 Capacitor not shown 1 20 708723 Inner Filter 24 x20 x12 x8B 1 21 OO1023 Eye Bolt 4 22 NH061000 Nut M6 4 23 10042 Nut 6 24 SR060600 Hex Socket Bolt M6x30 4 25 WF061620 Washer M6x16 4 26 SR089400 Hex Socket Bolt M8x16 1 27 SF069200 Pan Head Bolt W Flange M6x8 22 28 ST049200 Tapping Screw M4x8 28 29 BR000062 Ri...

Page 12: ...or Clip Set 1 54 WF061620 Flat Washer M6 4 55 330046 Pad 2 items are included with 708711 Remote Control Optional Replacement Filters 708722 Outer Filter cardboard frame 24 x20 x2 1 708724 Outer Filter metal frame washable 24 x20 x2 330025 Air Diffuser 24 x20 x1 1 708723 Inner Filter 24 x20 x12 x8B 1 Electrical Connections ...