background image

 

15

Maintenance 

Never perform maintenance on 

this machine before turning switch off and 
removing plug from power source. Failure to 
comply may cause serious injury!

 

Cleaning the Filter Bag – DC-1100BK and 
DC-1100MK 

 

Wearing a particle mask or 

respirator for protection against fine dust 
particles during cleaning is highly recommended. 

During first use and after cleaning, the filter bag may 
allow some dust to escape.  This is normal and will 
stop after a short period of time. 

Clean both the filter and collector bags frequently to 
keep the collector's performance at its optimum.  To 
clean: 

1. 

Disconnect the machine from the power source. 

2. 

Unhook the filter bag from the hanger and shake 
the bag so that the majority of the dust falls into 
the collector bag. 

3. 

Loosen the retaining strap, and remove the filter 
bag from the housing. 

4. 

Turn the bag inside out and clean. 

5. 

Turn the bag outside in and re-attach to the 
housing using the retainer strap to secure. 

Removing the Collector Bag–DC-1100BK 

1. 

Disconnect the machine from the power source. 

2. 

Remove the collector bag by pushing the ring of 
the collector bag upwards and pulling the bag 
out at an angle.   

3. 

Empty the contents into an appropriate 
container. 

4. 

Turn the bag inside out and clean. 

5. 

Turn the bag outside in and insert into the 
housing. 

To replace the collector bag, refer to 

Collector Bag 

Installation 

on page 11. 

Use the proper type hose to connect the dust 
collector to the machine being operated.  Dryer vent 
hose is not acceptable for this purpose.  Contact your 
nearest JET distributor for the full line of JET 

Dust 

Collector Hoses and Accessories

.  Customize your 

installation and obtain maximum performance with 
JET dust hoods, hoses, clamps, fittings, and blast 
gates. 

Cleaning the Filter – DC-1100CK 

Never perform maintenance on 

this machine before turning switch off and 
removing plug from power source. Failure to 
comply may cause serious injury!

 

Clean both the canister filter and collector bags 
frequently to keep the collector's performance at its 
optimum. 

To clean the filter, turn the handle a couple of 
rotations so the dust falls into the collection bag. 

Removing the Collector Bag–DC-1100CK 
and DC-1100MK 

Wearing a particle mask or 

respirator for protection against fine dust 
particles during cleaning is highly recommended. 

1.  Disconnect the machine from the power source 

outlet. 

2. 

Remove the collector bag by pushing the ring of 
the collector bag upwards at an angle and 
pulling the bag and snap ring out. 

3.  Empty the contents into an appropriate 

container. 

To replace the collector bag, refer to the 

Collector 

Bag 

Installation

 

on page 12. 

Motor 

Make frequent inspections of the motor fan and blow 
out (with low pressure air hose) or vacuum any 
accumulation of foreign material in order to maintain 
normal motor ventilation.   

Connecting the Dust Collector to a 
Machine 

Use the proper type hose to connect the dust 
collector to the machine being operated. Dryer vent 
hose is not acceptable for this purpose. Contact your 
nearest JET distributor for the full line of JET Dust 
Collector Hoses and Accessories. Customize your 
installation and obtain maximum performance with 
JET dust hoods, hoses, clamps, fittings, and blast 
gates. 

Grounding the Dust Collection System 

The dust collection system includes the dust collector 
and the hose, or ductwork you use to connect the 
tools. The dust collector is grounded through the 
ground wire in the cord. The hose or ductwork you 
use to connect the tool to the dust collector must also 
be grounded.   

Summary of Contents for DC-1100CK

Page 1: ...ctor Models DC 1100BK 1100CK 1100MK DC 1100BK DC 1100CK WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Part No M 708636 Ph 800 274 6848 Revision E 03 2011 www waltermeier...

Page 2: ...ge prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must a...

Page 3: ...achine On Off 13 All Models 13 Remote Control Optional Accessory 13 Dust Collector RF Remote Power Control Optional 13 Turning the DC RC On Off 13 Changing Operating Frequency 14 Installing the DC RC...

Page 4: ...ystalline silica from bricks cement and other masonry products Arsenic and chromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduc...

Page 5: ...emove loose items and unnecessary work pieces from the area before starting the machine 29 Never place hands near the inlet of the machine 30 Always make certain machine is off and unplugged when maki...

Page 6: ...on Filter Bag Kit Stock Number 708636MF Filter Bag Efficiency 98 of 5 micron particles 92 of 3 micron 74 of 1 micron Filter Bag Length installed in 32 Filter and Collector Bag Diameter in 20 Collector...

Page 7: ...it SN 708636 30M Filter Bag Kit SN 708636F 5M Filter Bag Kit SN 708636MF Canister Filter Kit SN 708639B DC 1100BK x x DC 1100CK x x DC 1100MK x x Table DC 1100 Dust Collector cartons Hardware Bag for...

Page 8: ...U 4 Knobs V Canister Filter Kit Contents Canister Filter Hardware SN DC1100 CHP Canister Filter Hardware 30 Micron Bag Filter Kit SN 708636F 1 Upper Bag Hanger Y 1 Hanger Bracket Z 1 Collector Bag X 1...

Page 9: ...ch M8 x 16 hex cap screws and M8 flat washers B Tighten with a 13mm wrench The dust collector must not be connected to the power source during assembly Failure to comply may result in serious injury R...

Page 10: ...t necessary for canister filter units 7 Tighten all nuts and bolts at this time with a 13mm wrench Hose Referring to Figure 6 8 Attach the hose B between the collector housing A and the impeller housi...

Page 11: ...ollector Bag Installation 30 Micron Kit Referring to Figure 8 4 Insert the ring of the collector bag A at an angle into the housing B through the opening at the bottom Pull down on the bag to make sur...

Page 12: ...ing A Fig 5 and tighten the knobs on the canister filter Figure 9 Collector Bag 3 Place the snap ring over the top of the plastic bag and fold the bag over the ring approximately three inches as shown...

Page 13: ...ed for activating Dust Collection units powered by 115V only up to 1 1 2HP If your dust collector is currently set up for 230V operation or you choose to convert it to 230V at a later time you must pu...

Page 14: ...device as described in Turning the DC RC On Off and verify that other devices using the same type remote control do not turn on Figure 14 Installing the DC RC Remote Power Control Optional Accessory...

Page 15: ...maximum performance with JET dust hoods hoses clamps fittings and blast gates Cleaning the Filter DC 1100CK Never perform maintenance on this machine before turning switch off and removing plug from...

Page 16: ...16 Parts Breakdown DC 1100 Dust Collectors...

Page 17: ...420051 Motor Packing 1 10 AB411040 Impeller 11 1 11 411036W Inlet Guard 1 12 427028 Inlet Port 2 4 1 13 420203 Inlet Cap 1 14 430034 Inlet Flange Packing 1 15 411041W Base 1 16 402036 Pivoting Caster...

Page 18: ...1 8 331051 Soft Grip Handle 2 9 TS 1540041 Hex Nut M6 8 10 708739 Filter 1 11 331052 Shaft 1 12 TS 1482041 Hex Cap Screw M6X20 4 13 TS 2361061 Lock Washer M6 4 14 TS 1550041 Flat Washer M6 4 15 331012...

Page 19: ...636F Index No Part No Description Size Qty 708636F 30 Micron Filter and Collection Bag Kit index 1 5 1 708698 Filter Bag 30 Micron 1 2 AB410012 Retainer Strap 1 3 708699A Collector Bag 1 4 430038 Hang...

Page 20: ...art No Description Size Qty 708636MF 5 Micron Filter and Collection Bag Kit index 1 6 1 708706 Filter Bag 5 Micron 1 2 AB410012 Retainer Strap 1 3 331038 Snap Ring 1 4 709563 Plastic Bag Package of 5...

Page 21: ...21 Wiring Diagram DC 1100 Dust Collectors...

Page 22: ...22 NOTES...

Page 23: ...23...

Page 24: ...24 WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www waltermeier com...

Reviews: