13
Electrical Connections
All electrical connections must
be done by a qualified
electrician. All adjustments or repairs must be
done with the dust collector disconnected from
the power source, unplugged. Failure to comply
may result in serious injury!
The DC-1100VX dust collectors (all models) are rated
at
115/230V, Prewired 115V
. Use a plug and outlet
rated at least 20 amps. The circuit for the machine
should also be protected by a minimum 20 amp
circuit breaker or fuse. Keep in mind that a circuit
being used by other machines, tools, lights, heaters,
etc. at the same time will add to the electrical load.
A dedicated circuit to the dust collector will give you
the best results since dust collectors are generally
used at the same time other tools are running.
Turning the Machine On & Off
This machine is intended for
indoor use only.
All Models
Before hooking up to the power source, make sure
that the switch is in the off position.
Turn the dust collector on by pressing the
Start
button mounted next to the motor. Press the
Stop
button to turn off the dust collector.
Remote Control
(Optional Accessory)
The DC-RC RF Remote Power Control unit is
available as an optional accessory (see your dealer
or contact Customer Service by calling the number
on the cover).
Important:
The DC-RC Remote Power Control (SN
708636C)
can be used for activating Dust Collection
units powered by 115V
only
up to 1-1/2HP. If your
dust collector is currently set up for 230V operation or
you choose to convert it to 230V at a later time, you
must purchase the DC-RC230 Remote Power
Control unit (SN 708636D).
Figure 13A Figure 13B
Dust Collector RF Remote
Power Control
(Optional)
The
DC-RC
Remote Power Control
(Figure 14)
should be used for activating Dust Collection units
powered by 115V only up to 1-1/2HP. The DC-RC
Remote Power Control
unit is rated at
115V, Single
Phase
only. Use an outlet rated at least 20 amps.
The circuit for the device being controlled by the DC-
RC
should also be protected by a minimum 20 amp
circuit breaker or fuse.
Before hooking up to the power source, make sure
that the switch is initially in the off position on both
the dust collector and
remote control unit
(Figure 13).
Turning the DC-RC
On & Off
This machine is intended for
indoor use only.
1. Plug the dust collector into the
main unit
(Figure 14) and plug the main unit into the power
outlet.
To start a machine or device:
2. Turn the machine itself on.
3. On the main unit place the switch to the
ON
position (Figure 13A). The red LED on the main
unit should light up.
4. Press the button on the
remote control
transmitter
(Figure 14) to turn the machine on.
5. To stop the machine, press the button on the
remote control transmitter
again.
Figure 14
When the machine is running, it can be stopped by
placing the switch on the main unit in the off position
(Figure 13B). To restart, repeat steps 3 and 4.