Do not operate the machine under the 
influence of drugs, alcohol or any 
medication. Be aware that medication 
can change your behaviour.  

Keep children and visitors a safe 
distance from the work area. 

Never leave a running machine 
unattended. Before you leave the 
workplace switch off the unit. 

Do not operate the electric tool near 
inflammable liquids or gases. 
Observe the fire fighting and fire alert 
options, for example the fire 
extinguisher operation and place. 

Do not use the dust collector in a dump 
environment and do not expose it to 
rain. 

Do not use this equipment to filter 
volatile fumes or smoke. 

Wood dust is explosive and can also 
represent a risk to health. 
Dust form some tropical woods in 
particular, and from hardwoods like 
beach and oak, is classified as a 
carcinogenic substance. 

Connection and repair work on the 
electrical installation may be carried 
out by a qualified electrician only. 

Have a damaged or worn power cord 
replaced immediately. 

3.3 Remaining hazards 

When using the machine according to 
regulations some remaining hazards 
may still exist. 

Dust can cause injuries. 

The use of incorrect mains supply or a 
damaged power cord can lead to 
injuries caused by electricity. 

Danger of explosion if not properly 
grounded. 

4.  Machine specifications 

4.1 Technical data 

Dust inlet 

Ø125mm (2xØ100mm) 

Air flow Ø125 

1200 m³/h 

Vacuum pressure 

1880Pa 

Collector bag capacity 

150L 

 

Overall DC-1200:                                         
(LxWxH) 

1000x750x2000mm 

Net weight 

38 kg 

Overall DC-1200CK-M/T:                                         
(LxWxH) 

1000x750x1900mm 

Net weight 

47 kg 

 

Mains 

230V ~1/N/PE  50Hz 

Input power 

1,5kW (2HP) S1 

Reference current 

7.3 A 

Extension cord     (H07RN-F)3x1,5mm² 
Installation fuse protection 

16A 

 

Mains 

~400V,3L/PE, 50Hz 

Motor input power 

1,5kW (2HP) S1 

Reference current 

2,8 A 

Extension cord (H07RN-F)  4x1.5mm² 
Installation fuse protection 

10A 

Isolation class 

4.2 Noise emission 

Acoustic pressure level (EN ISO 3744):  
80 dB (A). 

The specified values are emission 
levels and are not necessarily to be 
seen as safe operating levels. 
As workplace conditions vary, this 
information is intended to allow the user 
to make a better estimation of the 
hazards and risks involved only. 

4.3 Content of delivery 

Filter bag 
Collection bag  
Mobile casters (4x) 
Dust inlet 2 x 100 mm  
Hose clamps (2x

4”) 

Hose ground wire 
Operating manual 
Spare parts list 

4.4 Unit description

 

 

                     Fig 1 

                           

Fig1A 

 

Fig 2 

A….Connector Hose 
B….Collector Body & Fan/Motor                                                               
Assembly 
C….Collector 
D….Base 
E….Upper Bag Support 
F…. Support 
G….Inlet 
H….Filter Bag 
I…..Packing 
J….Four Casters 
K…. Hex. Bolt (M8x16 ,    18pc;                           
M8x25,   4pc;  M6x20,     6pc; )        
Hex.Nuts  (M8,    4pc;  M6,    6pc);                      
Head Screws(M6x10,   16pc);       
Washer (M8,   26pc ;  M6,    28pc);          
Hex. Wrench(5,   1pc) 
L…. Motor Base  
M…Handle 
N

….Bag Clamp (2pc) 

O

….Hose 

P

…..Hose Clamp 

Q

…..Collecter Bag  

R

…..Switch 

S

……Motor 

T……Plug(400V)  or Wire Plug(230V) 
W

……Outlet                                             

Y……..Cartridge Filter 

5.  Assembly and start up 

5.1 Assembly 

If you notice transport damage while 
unpacking, notify your supplier 
immediately. Do not operate the unit! 

Dispose of the packing in an 
environmentally friendly manner. 

Base: 

Install four casters to the under side of 
the base with bolts, lock washers 
washers and nuts (Fig 3) 

Summary of Contents for DC-1200

Page 1: ... DC 1200CK M DC 1200CK T Dust Collector Dust Collector with Canister Original GB Operating Instructions TOOL FRANCE SARL 9 Rue des Pyrénées 91090 LISSES France www jettools com 10001057M T 10000078M T 2019 03 ...

Page 2: ...2014 30 EU electromagnetic compatibility elektromagnetische Verträglichkeit compatibilité électromagnétique 2011 65 EU RoHS directive RoHS Richtlinie Directive RoHS designed in consideration of the standards und entsprechend folgender zusätzlicher Normen entwickelt wurde et été développé dans le respect des normes complémentaires suivantes EN 60335 1 2012 A11 2014 EN 60335 2 69 2012 EN 62233 2008 ...

Page 3: ...rer Materials such as liquids metal shavings metal dust screws glass plastic or rock can cause sparks and or damage when coming into contact with any part of the dust collector The product is not suitable for use in wet or humid environment Don t use appliance in places with a risk of explosion The proper use also includes compliance with the operating and maintenance instructions given in this ma...

Page 4: ...0mm Net weight 38 kg Overall DC 1200CK M T LxWxH 1000x750x1900mm Net weight 47 kg Mains 230V 1 N PE 50Hz Input power 1 5kW 2HP S1 Reference current 7 3 A Extension cord H07RN F 3x1 5mm Installation fuse protection 16A Mains 400V 3L PE 50Hz Motor input power 1 5kW 2HP S1 Reference current 2 8 A Extension cord H07RN F 4x1 5mm Installation fuse protection 10A Isolation class B 4 2 Noise emission Acou...

Page 5: ...ig 7 Install the housing A Fig 8 with 6 hex cap screws Fig 8 Hose Attach the hose A Fig 9 with 2 provided clamps B Fig 9 Install the filter bag DC 1200 Attach the loop of the filter bag to the filter bag hanger M Place the filter bag A over the bag support housing Place a bag clamp B over the bag and close the clamp Fig 10 Note make sure the bag is fastened securely so that no dust will escape dur...

Page 6: ...nance work on the electrical system may only be carried out by a qualified electrician 7 1 Cleaning Filters Shake the filter bag whenever it is clogged and before each collector bag change When the air flow reduces the filter must be cleaned To clean the filter on DC 1200CK M T turn the handle I Fig 10A a couple of rotations so the dust falls into the collector bag ATTENTION During the changing or...