8
Fig 10
Filter bag (DC-1900A):
Attach the bag support rods (A, Fig
11).
Fig 11
Install the filter bags with retainer
straps (D).
Canister filter (DC-1900CK):
Mount the handle (I, Fig 12) with 2 hex
nuts (G), flat wasshers (H) and a lock
washer (J).
Fig 12
Mount the canister filter with 4 knobs
(K) on the collector housing.
5.2 Dust connection
The hose or ductwork you use to
connect the tool to the dust collector
must be grounded for avoiding
explosion.
(JET Dust Collector Grounding Kit,
Article Number: JW1053).
5.3 Mains connection
Mains connection and any extension
cords used must comply with
applicable regulations.
The mains voltage must comply with
the information on the machine licence
plate.
The mains connection must have a
16 A surge-proof fuse.
Only use power cords marked H07RN-
F
Connections and repairs to the
electrical equipment may only be
carried out by qualified electricians.
6. Machine operation
You can start the machine with the
green ON button. The red OFF button
stops the machine.
7. Maintenance and inspection
General notes:
Maintenance, cleaning and repair
work may only be carried out after
the machine is protected against
accidental starting by pulling the
mains plug.
Inspect the proper function of the dust
collection system daily.
Clean the unit regularly.
Defective safety devices must be
replaced immediately.
Repair and maintenance work on the
electrical system may only be carried
out by a qualified electrician.
7.1 Cleaning Filter
When the air flow reduces the filter
must be cleaned.
To clean the filter on DC-1900CK, turn
the handle (I, Fig 12) a couple of
rotations so the dust falls into the
collector bag.
ATTENTION:
During the changing or cleaning of the
filters it’s necessary to use a mask
(mask with filtration).
7.2 Changing collector bag
Always disconnect the dust collector
from the power source (unplug) before
servicing or changing filters.
During the changing or cleaning of the
collector bag it’s necessary to use a
mask (mask with filtration).
Remove the collector bag by pushing
the snap ring (E, Fig 9) of the collector
bag upwards at an angle and pulling
the bag and snap ring out.
8. Trouble shooting
Unit doesn’t start
*No electricity-
check mains and fuse.
*Defective switch, motor or cord-
consult an electrician.
Air flow too weak
*
Clogged filter-
Clean filter.
9. Environmental protection
Protect the environment.