6.0

  Setup and assembly 

Carton contents: 

1  

Dust Collector 

4” to 3” adaptors 

2 Filters 

(pre-installed) 

4 Caster 

assemblies 

16 Washer 

Head Screws, 5/16” x 1/2" 

Open End Wrench, 10-12mm 

 

 

 

Figure 1 

1.  Turn dust collector upside down, with help 

from an assistant. Assemble casters to 
plates with the washer head screws. See 
Figure 1. 

 

7.0

  Electrical connections 

The JDC-500 Dust Collector is rated at 
115/230V power, pre-wired for 115 volt, and 
supplied with a plug. 

Before connecting to power source, be sure 
switch is in 

off 

position.  

It is recommended that the dust collector, when 
operated on 

115 volt power

, be connected to a 

dedicated 20 amp circuit with a 30 amp circuit 
breaker or time-delay fuse marked “D”. When 
operated on 

230 volt power

, it is recommended 

that the dust collector be connected to a 
dedicated 15 amp circuit with a 20 amp circuit 

breaker or time-delay fuse marked “D”.  

Local 

codes take precedence over recom-
mendations. 

7.1

  Grounding instructions 

1. All Grounded, Cord-connected Tools: 

In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This tool is equipped with an electric cord 
having an equipment-grounding conductor and a 
grounding plug. The plug must be plugged into a 
matching outlet that is properly installed and 
grounded in accordance with all local codes and 
ordinances. 

Do not modify the plug provided - if it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 

Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor with insulation 
having an outer surface that is green with or 
without yellow stripes is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 

 Check with a qualified 

electrician or service pe

r

sonnel if the 

grounding instructions are not completely 
understood, or if in doubt as to whether the 
tool is properly grounded. Failure to comply 
may cause serious or fatal injury.

 

Use only 3-wire extension cords that have 3-
prong grounding plugs and 3-pole receptacles 
that accept the tool's plug. 

Repair or replace damaged or worn cord 
immediately. 

2. Grounded, cord-connected tools intended for 
use on a supply circuit having a nominal rating 

less than 150

 volts: 

This tool is intended for use on a circuit that has 
an outlet that looks like the one illustrated in 

A, 

Figure 2. An adapter, shown in 

B

 and 

C

, may be 

used to connect this plug to a 2-pole receptacle 
as shown in 

B

 if a properly grounded outlet is 

not available. The temporary adapter should be 
used only until a properly grounded outlet can 
be installed by a qualified electrician. 

This 

adapter is not permitted in Canada.

 The green-

colored rigid ear, lug, and the like, extending 
from the adapter must be connected to a 
permanent ground such as a properly grounded 
outlet box. 

Summary of Contents for JDC-500

Page 1: ...anual Metal Dust Collector Model JDC 500 WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Part No M 414700 Ph 800 274 6848 Revision A 12 2011 www waltermeier com Copyright 2011 Walter Meier Manufacturing Inc ...

Page 2: ...stage prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must accompany the merchandise If our inspection discloses a defect we will repair or replace the product or refund the purchase price at our option We will return the repaired product or replacement at ...

Page 3: ...ns 6 6 0 Setup and assembly 7 7 0 Electrical connections 7 7 1 Grounding instructions 7 7 2 Voltage conversion 8 7 3 Extension cords 8 8 0 Operation 8 8 1 Control switch 8 9 0 Maintenance 9 10 0 Replacement Parts 9 10 1 1 JDC 500 Dust Collector Exploded View 10 10 1 2 JDC 500 Dust Collector Parts List 11 11 0 JDC 500 Dust Collector Wiring Diagram 12 ...

Page 4: ... in place at all times when the machine is in use If removed for maintenance purposes use extreme caution and replace the guards immediately after completion of maintenance 13 Check damaged parts Before further use of the machine a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function Check for alignment of movi...

Page 5: ...tions are not heeded it may result in serious injury or possibly even death 4 0 About this manual This manual is provided by Walter Meier Manufacturing Inc covering the safe operation and maintenance procedures for a JET Model JDC 500 Metal Dust Collector This manual contains instructions on installation safety precautions general operating procedures maintenance instructions and parts breakdown Y...

Page 6: ...on sparking Casters polyurethane Filters micro steel mesh Other Maximum capacity 490 cfm 13 88 cmm Maximum hose velocity 5610 fpm 1710 mpm Number of filters 2 Filter size 19 L x 9 5 w x 2 Thk 483 x 241 x 51 mm Filter efficiency 99 of 5 micron particles Number of dust ports 2 Dust port outside diameter 4 100 mm Dust port outside diameter with adaptor 3 76 2 mm Casters 2 1 2 64 mm diameter swivel Di...

Page 7: ...es Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician Improper connection of the equipment grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric co...

Page 8: ...extension cords is discouraged Try to place equipment within reach of the power source If an extension cord is necessary make sure it is in good condition and heavy enough to carry the current your product will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating Table 1 shows correct size to use depending on cord length and nameplate ampere rating I...

Page 9: ...800 hours of use See Figure 4 Figure 4 10 0 Replacement Parts Replacement parts are listed on the following pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday see our website for business hours www waltermeier com Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately ...

Page 10: ...10 10 1 1 JDC 500 Dust Collector Exploded View ...

Page 11: ...1 13 JDC 500013 Impeller Ø11 1 14 JDC 500014 Washer 1 15 TS 1503051 Socket Head Cap Screw M6x20 1 16 JDC 500016 Hose Adaptor 4 to 3 2 17 JDC 500017 Phillips Head Screw 3 16 x3 8 2 18 JDC 500018 Screw M4x8 16 19 JDC 500019 Handle 2 20 JDC 500020 Tapping Screw 4 21 JDC 500021 Phillips Head Screw 3 16 x3 8 3 22 JDC 500022 Pull Out Switch 1 23 JDC 500023 Moveable Door Plate 1 24 JDC 500024 Strain Reli...

Page 12: ...12 11 0 JDC 500 Dust Collector Wiring Diagram 115 V 230 V ...