27
Trouble Probable
Cause
Remedy
Motor failure.
If electric motor is suspect, you have
two options: Have a qualified
electrician test the motor for function
or remove the motor and take it to a
qualified electric motor repair shop
and have it tested.
Miswiring of the unit.
Double check to confirm all electrical
connections are correct. Refer to
appropriate wiring diagrams on pages
40 and 41 to make any needed
corrections.
Machine will not
start/restart or
repeatedly trips
circuit breaker or
blows fuses.
Switch failure.
If the start/stop switch is suspect, you
have two options: Have a qualified
electrician test the switch for function,
or purchase a new start/stop switch
and establish if that was the problem
on changeout.
Extension cord too light or too long.
Replace with adequate size and
length cord.
Band Saw does not
come up to speed.
Low current.
Contact a qualified electrician.