background image

 

 

13 of 17 

6.

 

SPARE PARTS  

 

PARTS DESCRIPTION 

QTY REQUIRED  

PART NUMBER  

FILTER HEPA H14 

JS-606/FILTER/H14 

FILTER HEPA H10 

JS-606/FILTER/H10 

FILTER HEPA F7 

JS-606/FILTER 

FILTER GASKET 

JS-606/33 

FAN ASSEMBLY  

MR280S-00001 

FAN GASKET 

JS-606/38 

FILTER COVER 

JS-606/FILTER/COVER 

SHAKER MOTOR 

8-708 

SHAKER MOTOR AV MOUNTS 

7-976 

 

 

 
 
 

 

Filter cover 

Filter  

Filter gasket 

Fan 

Shaker 
motor 

Fan gasket 

Shaker 
motor 
AV mounts 

Summary of Contents for JS-606 Series

Page 1: ...PERSONNEL CLEANING BOOTH EXTRACTOR ACM 0002 Issue 3...

Page 2: ...AL SAFETY INSTRUCTIONS 2 INSTALLATION GUIDE 3 EXTRACTOR OVERVIEW DRAWINGS 4 SET UP OPERATION 5 MAINTENANCE INSTRUCTIONS 6 SPARE PARTS 7 MALFUNCTION CAUSE REMEDY 8 WARRANTY INFORMATION 9 MANUFACTURER S...

Page 3: ...the installation must ensure that Only qualified personnel are entrusted to work on the unit These persons always have at their disposal the operating instructions and other product documentation supp...

Page 4: ...nly the castors to be fitted before its ready to be connected to the Cleaning Booth The extractor is powered directly from the Cleaning Booth via two IP67 Blue Cable Mount 2P E Industrial Power Plugs...

Page 5: ...5 of 17 3 EXTRACTOR OVERVIEW DRAWINGS Filter cover Shaker motor MR280S Fan Motor pedestal Fan Motor Trolley base X2 Locking wheels...

Page 6: ...6 of 17 Extractor inlet Extractor handle Filter cover handle Collection bag Motor pedestal Extractor drum...

Page 7: ...il needs connecting to the Cleaning Booth LEV system via 8mm flexible air tube If the extractor is not being used in conjunction with the Cleaning Booth the hose tail needs to be removed and replaced...

Page 8: ...8 of 17...

Page 9: ...9 of 17...

Page 10: ...h and will operate automatically without warning Extreme caution is advised when carrying out any maintenance to the equipment All electrical connections should be removed from the Cleaning Booth When...

Page 11: ...cated on top of the filter cover Use the X2 handles to lift the cover over the filter NOTE Cover weight 8Kg Remove the filter element by undoing X4 M10 hex head bolts and nuts Once these have been rem...

Page 12: ...solated from the electrical supply Waste collection bag removal Do not let the waste collection bag over fill See below image for maximum fill level The correct PPE must be worn when emptying the wast...

Page 13: ...HEPA H10 1 JS 606 FILTER H10 FILTER HEPA F7 1 JS 606 FILTER FILTER GASKET 1 JS 606 33 FAN ASSEMBLY 1 MR280S 00001 FAN GASKET 1 JS 606 38 FILTER COVER 1 JS 606 FILTER COVER SHAKER MOTOR 1 8 708 SHAKER...

Page 14: ...ng system Never run in isolation Motor has winding or bearing damage Contact supplier immediately Electrical supply problems Ensure that supply voltages match with the motor rating plate details Leak...

Page 15: ...es not extend the lifespan of the part The Warranty which covers the replacement part expires on the date of expiry of your equipment s Warranty Parts replaced under the Warranty become the property o...

Page 16: ...Products bearing the WEEE symbol should not be disposed of in general waste These should be taken to local facilities where they can be recycled free of charge This will ensure minimum impact on the...

Page 17: ...17 of 17 11 Declaration of Conformity...